70
11 Supplement
VEGAPULS 67 • 4 … 20 mA/HART - four-wire
36532-EN-160224
Torques
Max. torques
Ʋ
Mounting screws, mounting strap on
sensor housing
4 Nm (2.950 lbf ft)
Ʋ Flange screws, compression flange
DN 80
5 Nm (3.689 lbf ft)
Ʋ Flange screws, adapter flange DN 100
7 Nm (5.163 lbf ft)
Max. torques for NPT cable glands and Conduit tubes
Ʋ
Plastic housing
10 Nm (7.376 lbf ft)
Ʋ
Aluminium/Stainless steel housing
50 Nm (36.88 lbf ft)
Input variable
Measured variable
The measured quantity is the distance between the
end of the sensor antenna and the product surface. The
reference plane for the measurement is the lower side of
the flange.
3
4 2
1
Fig. 46: Data of the input variable
1 Reference plane
2 Measured variable, max. measuring range
3 Antenna length
4 Utilisable measuring range
Max. measuring range
15 m (49.21 ft)
Recommended measuring range
up to 15 m (49.21 ft)