69
11 Supplement
VEGAPULS 67 • 4 … 20 mA/HART - four-wire
36532-EN-160224
11 Supplement
11.1 Technical data
General data
316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
Ʋ Adapter flange
PP-GF30 black
Ʋ Seal, adapter flange
FKM (COG VI500), EPDM (COG AP310)
Ʋ
Antenna
PBT-GF 30
Ʋ
Focussing lense
PP
Materials, non-wetted parts
Ʋ Compression flange
PP-GF30 black
Ʋ
Mounting strap
316L
Ʋ
Fixing screws, mounting strap
316L
Ʋ Fixing screws, adapter flange
304
Ʋ
Plastic housing
plastic PBT (Polyester)
Ʋ
Aluminium die-casting housing
Aluminium die-casting AlSi10Mg, powder-coated - basis:
Polyester
Ʋ
Stainless steel housing
316L
Ʋ
Cable gland
PA, stainless steel, brass
Ʋ
Sealing, cable gland
NBR
Ʋ
Blind plug, cable gland
PA
Ʋ
Seal between housing and housing lid Silicone SI 850 R, NBR silicone-free
Ʋ
Inspection window in housing cover
(optional)
Polycarbonate
Ʋ
Ground terminal
316L
Process fittings
Ʋ
Flanges
DIN from DN 80, ASME from 3", JIS from DN 100 10K
Weight depending on process fitting and
housing material
0.7 … 3.4 kg (1.543 … 7.496 lbs)
Max. torques, version plastic horn antenna
Ʋ
Mounting screws, mounting strap on
sensor housing
4 Nm (2.950 lbf ft)
Ʋ Flange screws, compression flange
DN 80
5 Nm (3.689 lbf ft)
Ʋ Flange screws, adapter flange DN 100
7 Nm (5.163 lbf ft)
Max. torque for NPT cable glands and Conduit tubes
Ʋ
Plastic housing
10 Nm (7.376 lbf ft)
Ʋ
Aluminium/Stainless steel housing
50 Nm (36.88 lbf ft)