43
6 Set up with the indicating and adjustment module
VEGAFLEX 83 • 4 … 20 mA/HART - two-wire
41834-EN-120726
The default setting is "
Analogue current output
" and the address 00.
In this menu, you read out the instrument name and the instrument
serial number:
In this menu item, the hardware and software version of the sensor is
displayed.
In this menu item, the date of factory calibration of the sensor as well
as the date of the last change of sensor parameters are displayed via
the indicating and adjustment module or via the PC.
In this menu item, the features of the sensor such as approval, pro-
cess fitting, seal, measuring range, electronics, housing and others
are displayed.
6.4 Saving the parameter adjustment data
We recommended noting the adjusted data, e.g. in this operating
instructions manual, and archiving them afterwards. They are thus
available for multiple use or service purposes.
If the instrument is equipped with an indicating and adjustment
module, the data in the sensor can be saved in the indicating and
adjustment module. The procedure is described in the operating
instructions manual "
Indicating and adjustment module
" in the menu
item "
Copy sensor data
". The data remain there permanently even if
the sensor power supply fails.
The following data or settings for adjustment of the indicating and
adjustment module are saved:
Info/Instrument name
Info/Instrument version
Info/Factory calibration
date
Info/Sensor character-
istics