K5/K5N Vacuum Packaging Machine
Operation
2002-04-25
Art. no. 519.340
Page 2 8/56
No. Symbol
Name
Function
9
Vacuum pump
Used to switch the vacuum pump on and off.
If the vacuum chamber lid is down, it is opened by
pressing this button after switching on the machine at the
main I/O switch .
10
DOWN arrow
button
Lowers the value shown on LED display 1 or changes to
other possible settings.
11
Inert gas
Inert gas setpoint
The setpoint input may be between 400 and 999. 999
means “no inert gas”.
12
Welding
Welding setpoint
The setpoint can be set at between 0.0 and 5.0 seconds.
13
Cutting
Cutting setpoint
The setpoint can be set at between 0.0 and 5.0 seconds.
14
Intermediate
ventilation
Length of the intermediate ventilation
The time can be set to between 0.0 and 1.0 second(s).
15
DOWN arrow
button
Packaging program
:
Select the requested program number, descending.
Service program:
Select parameter levels S-04, S-03, S -02 and S-01 in
descending order. The parameter levels are displayed on
LED display 2.
16
Stop
Changes back to the basic setting from any position.
If you press this button during vacuum generation, you
proceed to the next stage of the program.
The individual parameters are described in detail in the section on “Program ming”.