05 - VB3i Logging
Logging modes
The logging method can be set within
.
There are three options which operate as described below.
Log continuously
With ‘log continuously’ ticked the VBOX will log data, regardless of movement, whenever powered with media detected.
Log only when moving
With ‘log only when moving’ ticked then the VBOX will only log data to the CF card when it detects speed >0.5 km/h.
Advanced
The advanced logging option on the VBOX 3i allows any of the logged data channels to be used to trigger the logging on
the VBOX.
This facility allows a threshold value to be set as either > or < so that the logging will start or stop when a data value is
exceeded (or not).
Multiple data channels can be combined in a Boolean ‘OR’ manner to control the logging.
Compact Flash Memory Cards
The VBOX stores logged data onto CF cards. The CF cards available from Racelogic are already optimised for use on
the VBOX and as such do not need formatting before use. Should the CF Card need formatting due to card errors it can
be done through Windows, as the VBOX supports the following format type:
• FAT
• FAT16
• FAT32
To guarantee compatibility with VBOX 3i, please purchase CF cards direct from
or
to confirm card compatibility.