23
7532
Mounting
3.4.5
Mounting with Sample hatch on stilling well
Installation tips
For control and cleaning purposes as well as for hand dipping (tape), a sample hatch
gauging is recommended. The sensor head can be easily checked in the area of the
opening. Manual gauging with gauge rod or tape is possible without removal of the
transmitter. The lower edge of the opening is the reference for the gauging. The
construction is only suitable for non-pressurized operation.
Note!
The nozzle for manual gauging is not part of the standard offering from Varec. Please
contact Varec for further information.
2)Only dimensions adapted to standard. Designed for non-pressurized operation only,
therefore thickness of flange can be reduced (e.g. 8mm).
Flange
DN150
DN200
DN250/300
Flange
ANSI 6"
ANSI 8"
ANSI 10"
PN [lbs]
2)
16
16
16
PN [lbs]
2)
150
150
150
A [mm]
110
140
170
A [mm]
110
140
170
L [mm}
—
300
450
L [mm]
—
300
450
L0
0-FM
R5
3xxx-06
-00
-0
0-en-00
4
Summary of Contents for 7532
Page 31: ...31 7532 Operation 5 Operation 5 1 Quick operation guide...
Page 44: ...Operation Radar Tank Gauge 44 Installation and Operations Manual...
Page 46: ...Commissioning Radar Tank Gauge 46 Installation and Operations Manual 6 3 Basic Setup...
Page 72: ...Commissioning Radar Tank Gauge 72 Installation and Operations Manual...
Page 74: ...Maintenance Radar Tank Gauge 74 Installation and Operations Manual...
Page 76: ...Accessories Radar Tank Gauge 76 Installation and Operations Manual...
Page 77: ...77 7532 Troubleshooting 9 Troubleshooting 9 1 Troubleshooting instructions...
Page 91: ...91 7532 Appendix 11 Appendix 11 1 Operating menu HART Display modul ToF Tool...
Page 105: ...7532 IOM027FVAE0804 105 Notes...