24
Chapter 4 Crane special inverter parameters lists
Function
code
number
Function code name
Factory
setting Setting range
Unit Property
Function code selection
Tens place: Version incompatible
Hundreds place: Reserve
Thousands place: Reserve
PA.20
Fault locking function
selection
0
0
~
1
/
○
0: Fault is not locked
1: Fault is locked
PA.21
Automatic reset times
0
0
~
20
/
○
0
~
20
PA.22
Automatic reset interval
2.0
2.0
~
20.0
s
○
2.0
~
20.0s
Group Pb Enhanced Function Parameters
Pb.00
Hopping frequency 1 low
limit
0.00
0.00
~
300.00
Hz
×
Setting range: P0.13~P0.14
Set hopping frequency range of inverter to avoid
mechanical resonance. When the setting frequency
of inverter is less than the hopping frequency, the
inverter will run automatically at the high limit or low
limit of the hopping frequency (change to run at low
limit of the hopping frequency when acceleration,
for deceleration, change to run at high limit of the
hopping frequency)
Pb.01
Hopping frequency 1 high
limit
0.00
0.00
~
300.00
Hz
×
Pb.02
Hopping frequency 2 low
limit
0.00
0.00
~
300.00
Hz
×
Pb.03
Hopping frequency 2 high
limit
0.00
0.00
~
300.00
Hz
×
Pb.04
Hopping frequency 3 low
limit
0.00
0.00
~
300.00
Hz
×
Pb.05 Hopping frequency 3 high
limit
0.00
0.00
~
300.00
Hz
×
Pb.15 Restart automatically after
power resumes narmal
0
0
~
1
/
×
0: Disabled
1: Enabled
Pb.16
Waiting time for restar
0.5
0.0
~
20.0
s
○
0.0
~
20.0s
Pb.23
Parameter copy
0
0
~
5
/
×
0: No function
1: Parameter upload
2: Parameter download (without motor parameters)
3: Parameter download (with motor parameters)
4: Parameter upload is prohibited
5: Parameter upload is allowed
Group PC Communication Parameters
PC.00
Communication baud rate
6
4
~
8
bps
○
4
:
4800 bps
;
5
:
9600 bps
;
6
:
19200 bps
;
7
:
38400 bps
;
8
:
57600 bps
;
PC.01
Data format
0
0
~
2
/
○
0: 1−8−1 format, no parity
1: 1−8−1 format, odd parity
2: 1−8−1 format, even parity
PC.02
Local address
1
1
~
247
/
○
1 ~ 247, 0 is broadcasting address
PC.03 Communication parameters
setting
303
000
~
F0F
/
○
303: communication write RAM
F0F: communication write EEPROM
Note: To avoid bad communication write EEPROM,
please keep the default value
Group Pd Vector Control 2 Parameters
Pd.00
Speed/torque control
00
00
~
21
/
○
Ones place: Speed control/torque control selection:
0: Speed control
1: Torque control
Tens place:Torque direction under torque control:
0: Determine by analog input
1: Consistent with the running direction
2: Inconsistent with the running direction
Pd.01
Speed loop proportional
gain 1
(ASR_P1)
2.00
0.000
~
30.00
/
○
Pd.02
Speed loop integral time 1
(ASR_I1)
0.200
0.000
~
6.000
s
○
Summary of Contents for V5 Series