high performance crane special inverter User Manual
Chapter 4 Crane special inverter parameters lists 19
Function
code
number
Function code name
Factory
setting Setting range
Unit Property
Function code selection
18: Acceleration and deceleration is prohibited
,
If this terminal function is enabled, the current
frequency output will be maintain except stop
command.
19: External fault input
,
When this terminal is ON,
inverter will stop running and display
“
E.oUt
”
fault.
20: Fault reset
21: external interrupt contact input, the output
frequency will be 0 immediately after this function is
effective, and the signal will be automatically
accelerated from 0 to the set frequency after
cancellation
22: Run is prohibited
,
Once this terminal function is
enable, the motor will coast to stop immediately.
The inverter is allowed to start only when this
terminal function is disabled.
23: The terminal is stopped. When this function is
valid, it will stop immediately according to the stop
mode.
24: Free stop at the terminal, this function is valid,
immediately free parking
25: Stop via terminal with DC braking 1
32: Brake release confirmation
:
33: Location synchronization
34: Forced location sync is invalid
35: The frequency is switched to P0.13. Once
closed, the frequency is switched to P0.13.
36: The frequency is switched to P0.05. Once
closed, the frequency is switched to P0.05.
37: Forward allows 1, if the forward run is
disconnected, then decelerate to stop
38: Reverse allows 1, if the reverse run is
disconnected, then decelerate to stop
39: Run permission 1, if the running state is
disconnected, decelerate to stop
40: Forward allows 2, if the forward rotation is
disconnected, free parking
41: Reverse allows 2, if the reverse run is
disconnected, free parking
42: Run permission 2, if the operation is
disconnected, free parking
Group P6 Analog Reference Parameters
P6.00
AI1 ~ AI3, DI analog curve
correction
4444
0000
~
4444
/
○
Ones place: AI1 analog curve correction
0: Determine the reference frequency
according to curve 1 (P6.01 to P6.04)
1: Determine the reference frequency
according to curve 2 (P6.05 to P6.08)
2: Determine the per unit value determined
according to curve 3 (P6.09 to P6.12)
3: Determine the per unit value determined
according to curve 4(P6.13 to P6.30)
4: Withput curve correction
Tens place: AI2 analog curve correction
Same with above
Hundreds place: AI3 analog curve correction
Same with above
Thousands place: DI analog curve correction
P6.01
Curve 1 input point A0
0.0
0.0
~
110.0
%
○
P6.02
Reference frequency f0
corresponding to curve1
input point A0
0.00
0.00
~
300.00
Hz
○
P6.03
Curve 1 input point A1
100.0
0.0
~
110.0
%
○
P6.04
Reference frequency f1
corresponding to curve1
input point A1
50.00
0.00
~
300.00
Hz
○
P6.05
Curve2 input point A0
0.0
0.0
~
110.0
%
○
P6.06
Reference frequency f0
corresponding to curve2
input point A0
0.00
0.00
~
300.00
Hz
○
P6.07
Curve2 input point A1
100.0
0.0
~
110.0
%
○