high performance crane special inverter User Manual
Chapter 4 Crane special inverter parameters lists 23
Function
code
number
Function code name
Factory
setting Setting range
Unit Property
Function code selection
0: Disabled
1: Enabled
Tens place: Under voltage regulation
0: Disabled
1: Enabled
Hundreds place: Over modulation
0: Disabled
1: Enabled
PA.07
Energy saving coefficient
0
0
~
50
%
○
0
~
50%
PA.08
Magnetic flux braking
selection
1
0
~
1
/
×
0: Disabled 1: Enabled
PA.09
Dynamic braking selection
1
0
~
1
/
×
0: Disabled 1: Enabled
PA.10 Brake unit action hysteresis
000
000
~
100
V
○
PA.11
Braking unit action voltage
720
650
~
750
V
○
PA.12
Relay action when the
inverter is fault
100
000
~
111
/
○
Ones place: Under voltage fault
0: Disabled
1: Enabled
Tens place: Auto reset interval
0: Disabled
1: Enabled
Hundreds place: Fault locking
0: Disabled
1: Enabled
PA.13
Inverter or motor overload
prealarm
000
000
~
111
/
○
Ones place: Detected value selection:
0: Motor overload pre−alarm, relative to motor
rated current
1: Inverter overload pre−alarm, relative to inverter
rated current
Tens place: Action after overload pre−alarm:
0: Continue running
1: Report overload fault and stop
Hundreds place: Detecting condition selection
0: Detect all the time
1: Only detect at constant speed
PA.14
Overload pre−alarm
detection level
130.0
20.0
~
200.0
%
○
20.0
~
200.0%
PA.15
Overload pre−alarm
detection time
5.0
0.1
~
60.0
s
○
0.1
~
60.0s
PA.16 Fault shielded and alarm
attribute setting 1
0020
0000
~
2222
/
○
Ones place: Output−ground short
circuit
Tens place: Power failure during
running
Hundreds place: Input power
error
Thousands place: Output phase
failure
;
0: The fault is not
blocked, and the
fault is stopped;
1: The fault is not
blocked, and the
alarm does not
stop;
2: The fault has
been blocked, no
alarm and no
downtime
PA.17
Fault shielded and alarm
attribute setting 2
0000
0000
~
2222
/
○
Ones place: EEPROM error
Tens place: Relay contact
open/close failure
Hundreds place: Sensor taking
sample anomaly
Thousands place: Encoder
disconnection
PA.18 Fault shielded and alarm
attribute setting 3
2000
0000
~
2222
/
Ones place: +10V output error
Tens place: Analog input error
Hundreds place: Motor over
temperature (PTC)
Thousands place:
Communication fault 1 (operation
panel 485)
PA.19
Fault shielded and alarm
attribute setting 4
0002
0000
~
2222
/
○
Ones place: Communication fault
2(terminal 485)
Summary of Contents for V5 Series