high performance crane special inverter User Manual
Chapter 4 Crane special inverter parameters lists 21
Function
code
number
Function code name
Factory
setting Setting range
Unit Property
Function code selection
function selection
5: Stop and lock due to under voltage (LU)
6: Stop due to external failure (EXT)
7: Frequency high limit(FHL)
8: Frequency low limit(FLL)
9: Inverter is running at zero speed
10~12: reserved
13:Inverter ready completed
14: Inverter failure 15: Inverter reports alarm
19: Output X1 20: Output X2
22: Zero current detection arrival (relative to motor)
23: Stop command indication
32: Brake control 33~47: reserved
P7.03
AO1 terminal output
function selection
48
48
~
71
/
48
:
Output operating frequency
49
:
Output setting frequency
50
:
Output current 51
:
Output motor current
52
:
Output torque 53
:
Output voltage
54
:
Bus voltage 55
:
AI1
56
:
AI2 57
:
AI3
58
:
DI 59
:
Output power
P7.04
AO2 terminal output
function selection
49
48
~
71
/
○
P7.05
AO1 gain
100.0
0.0
~
200.0
%
○
P7.06
AOAO1 bias
0.0
0.0
~
200.0
%
○
P7.07
AO2 gain
100.0
0.0
~
200.0
%
○
P7.08
AO2 bias
0.0
0.0
~
200.0
%
○
P7.20
FDT1 level high limit
3.00
0.00
~
300.00
Hz
○
FDT function can be used for less demanding
brake control, such as truck, car and other
translation mechanism
P7.21
FDT1 level low limit
2.90
0.00
~
300.00
Hz
○
P7.22
FDT2 level high limit
3.50
0.00
~
300.00
Hz
○
FDT function can be used for less demanding
brake control, such as truck, car and other
translation mechanism
P7.23
FDT2 level low limit
3.40
0.00
~
300.00
Hz
○
P7.25
Terminal effiective status
selection
0000
0000
~
1131
/
○
Ones place: Multi function input terminal Xi:
0: If Xi have current flowing, Xi is enabled
1: If Xi without current flowing, Xi is enabled
Hundreds place: Relay terminal:
Ten digits: Multi-function output terminal Yi
0: Y1 current is valid; Y2 current is valid;
1: Y1 has no current effective; Y2 current is valid;
2: Y1 current is valid; Y2 has no current effective;
3: Y1 has no current effective; Y2 has no current
effective;
Hundreds place: relay output terminal
0: If relay enabled, relay is in magnetizing status
1: If relay enabled, relay is not in magnetizing
status
Thousands place: reserved
Group P8 monitoring parameters
P8.00
Overspeed detection level
110.0
0.0
~
200.0
%
○
P8.00 is the percentage of the relative maximum
frequency P0.11. If the actual speed exceeds the
overspeed detection level and continues for the
time set by P8.01, the inverter reports an
overspeed fault.
P8.01
Overspeed detection delay 0.200
0.000
~
60.000
s
○
P8.02
Stall detection level
8.00
0.00
~
300.00
Hz
○
If the deviation between the actual speed and the
given speed is greater than the stall detection level
and continues for the time set by P8.03, the inverter
reports a stall failure.
P8.03
Stall detection delay
0.200
0.000
~
60.000
s
○