WARNING
The window unit must be correctly
installed, fastened and sealed after
servicing or serious bodily injury and/or
damage to the appliance may result.
To ensure a safe operation:
• Double-check that the window frame is
correctly installed;
• Verify that the four bolts are hooked
properly to the window tabs then;
• Pull out the sides of the window and
release to ensure it returns to its position
and the springs are working;
• Press all around the window frame
against the firebox to ensure the window
is well sealed before operation.
WARNING
Failure to install the window correctly can:
• Leak carbon monoxide;
• Affect the performance of the fireplace;
• Damage components;
• Cause overheating resulting in dangerous
conditions.
Damages caused by incorrect window
installation is not covered by the Valor
warranty.
Installation
Refit & Check Window
Re
fi
t and Check Window
1. Hook the glass window to the
fi
rebox then fastten
the four bolts pushing and turning them 90 degrees.
Verify that each bolt is properly hooked by feeling
with your
fi
ngers and ensuring the pin of the bolt
is hooked to the
fi
replace’s
fl
ange.
2. Pull out the window by the sides and release it to
check that it opens slightly and returns con
fi
rming
the good function of the spring-loaded mechanism.
3. Apply
fi
rm pressure around the window frame to
ensure the window is sealed tight against the
fi
re-
box.
4.
If the Hot Glass Warning plate has been removed
from the front lower corner of the window, re-
install it by sliding it between the glass and the
frame as indicated.
Hot Glass Plate
x 4