Valor RetroFire RF24JDN Installation Manual Download Page 2

2

Ce guide est disponible en français sur demande.

This appliance is a domestic room-

heating appliance. It must not be used 

for any other purposes such as drying 

clothes, etc.

This appliance is suitable for 

installation in a bedroom or bed 

sitting room.

The information contained in this manual is believed to 

be correct at the time of printing. Miles Industries Ltd. 

reserves the right to change or modify any information 

or speci

fi

cations without notice. Miles Industries Ltd. 

grants no warranty, implied or stated, for the 

installation or maintenance of your heater, and 

assumes no responsibility for any consequential 

damage(s).

© Copyright Miles Industries Ltd., 2022. All rights reserved.

Designed and manufactured for Miles Industries Ltd

.

Valor Fireplaces

190–2255 Dollarton Highway 

North Vancouver, BC, Canada  V7H 3B1

T

604.984.3496  F

604.984.0246

valor

fi

 replaces.com

This appliance may be installed in an 

after-market permanently located, 

manufactured (mobile) home where 

not prohibited by local codes. This 

appliance is only for use with the type 

of gas indicated on the rating plate. 

This appliance is not convertible for 

use with other gases, unless a certi

fi

ed 

kit is used.

INSTALLER: Leave this manual with the 

appliance.
CONSUMER: Retain this manual for 

future reference.

 Massachusetts: 

The piping and 

fi

nal gas connection must be 

performed by a licensed plumber or gas 

fi

tter in 

the State of Massachusetts. Also, see Carbon 

Monoxide Detector requirements in this manual.

WARNING

This product can expose you to chemicals 

including Benzene, which is known to the State 

of California to cause cancer and birth defects or 

other reproductive harm. For more information 

go to www.P65Warnings.ca.gov.

Note: Natural gas, in its original state, contains 

Benzene. 

Summary of Contents for RetroFire RF24JDN

Page 1: ...ial propane gas with with WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your bui...

Page 2: ...Highway North Vancouver BC Canada V7H 3B1 T 604 984 3496 F 604 984 0246 valorfireplaces com This appliance may be installed in an after market permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used INST...

Page 3: ...t Terminal Location 18 Preparation 19 Existing Fireplace Preparation 19 Before Installation 20 Installation 21 Window Burner Removal 21 Install Vent Plate 22 Connect Venting Co Linear 23 Connect Venting Co Axial 24 Reassemble Appliance 25 Connect Gas Supply 27 Install Fuel Bed 28 Traditional Log Set MF28LSK 28 Driftwood Kit MF28DWK 30 Refit Check Window 32 Install Battery Holder 33 Pair Remote Con...

Page 4: ...ens are installed Some materials or items although safe may discolor shrink warp crack peel and so on because of the heat produced by the fireplace Avoid placing candles paintings photos and other combustible objects sensitive to heat or furniture within 36 inches 0 9 m around the fireplace Solid wood flooring in front of the fireplace if allowed may shrink during the heating season due to heat Du...

Page 5: ...ass front removed cracked or broken Replacement of the glass should be done by a licensed or qualified service person Intended use This appliance is designed and approved as a supple mental heater and provides the potential for most energy conservation when used while attended The use of an alternate primary heat source is advisable This unit is not for use with solid fuel Do not use this heater a...

Page 6: ...ions This appliance is shipped without a vent plate A vent plate is required for every installation Either RA24CL Co linear vent plate 3 x 3 or RA24CA Co axial vent plate 5 x 3 RA24CL OR RA24CA RF24JDN RF24JDP with ...

Page 7: ... detailed location see Dimensions on page 11 or page 16 Gas Conversion Kits The RF24JD is supplied as natural gas or propane gas and is field convertible between fuels See instructions packaged with the conversion kits for further details Electrical The RF24JD does not require an electrical power source unless fitted with the optional 555CFK Circulating Fan Kit in which case a grounded power sourc...

Page 8: ...manual for co axial and co linear venting components Note When using the RA24CA Co Axial Vent Plate use the 590FVK2 5 x 3 Co Axial Flex Vent and Terminal Adapter Flashing Decorative Cast Iron Frets RA24FK Fret Kit required for all frets RA24CV Contemporary Vintage Iron Finish RA24TB Tradtional Black Finish 1225VFB Ventana Fret Black Gas Conversion Kits RA24JDNK Conversion to natural gas RA24JDPK C...

Page 9: ...items although safe may discolor shrink warp crack peel and so on because of the heat produced by the fireplace Avoid placing candles paintings photos and other items sensitive to heat around the fireplace WARNING HOT HEARTH FLOOR The hearth or floor in front of the fireplace may become very hot when the fireplace heats Do not use the hearth as a seat or shelf Solid wood flooring in front of the f...

Page 10: ...3 Co Linear Vent Plate with AutoFire supplied separately Co Linear Vent Plate RA24CL Sidewall co linear installation into existing F P using 720SWK see installation instructions supplied with 720SWK Min 3 0 Max 5 0 Between 3 and 5 fully open restrictors Beyond 5 0 the sidewall terminal may be used but leave restrictors opened at mid point as supplied 720SWK Terminal 3 Liners 3 min Bend Radius RF24...

Page 11: ...ies having a combination of all the minimum dimensions shown possible may prove to be difficult installations 24 1 2 8 27 10 RA24TB Fret Black 1225VFB Ventana Fret Black RA24CV Fret Vintage Iron Optional Frets 24 3 8 7 5 8 18 18 20 27 Height to Smoke Curtain Minimum Insert Cavity 14 without fret 15 3 4 with fret IMPORTANT A free space of 3 4 inch 19 mm is required in front of the barrier screen to a...

Page 12: ...ing may be converted to solid 4 x 6 5 8 co axial venting at the top of the existing solid fuel burning chimney as necessary where the exist ing chimney has deteriorated and been removed The conversion must be done using approved com ponents see page 40 and proper vent clearances to combustibles must be maintained Flex lilners may only be installed into solid fule burn ing fireplaces and chimney sy...

Page 13: ...ical terminal installation for an 8 diameter air cooled chimney system Sidewall Termination ONLY with Valor 720SWK See instructions provided with kit Co Linear with RA24CL Vent Termination 559SFK Flashing cut to required size and form drip edge on site 559CLT Terminal Fasten to Flashing with Sheet Metal Screws 3 locations 2 3 Flex Liners 18 18 Existing Air Cooled Chimney Factory Built Fireplaces R...

Page 14: ...safe may discolor shrink warp crack peel and so on because of the heat produced by the fireplace Avoid placing candles paintings photos and other items sensitive to heat around the fireplace WARNING HOT HEARTH FLOOR The hearth or floor in front of the fireplace may become very hot when the fireplace heats Do not use the hearth as a seat or shelf Solid wood flooring in front of the fireplace if all...

Page 15: ...n Terminal adapter with flashing supplied with 590FVK2 Approved 6 5 8 x 4 co axial terminal Co linear installation into existing F P RF24JD with RA24CA Co axial Vent Plate RF24JDN P appliance supplied without vent plate RA24CA 5 x 3 Co axial Vent Plate packed separately Co axial Vent Plate 18 18 6 5 8 x 4 collars Terminal Adapter with Flashing 3 Flex pipe in 5 Flex pipe shown compressed 590FVK2 Fl...

Page 16: ... Frets 24 3 8 7 5 8 18 18 20 27 Height to Smoke Curtain Minimum Insert Cavity 14 without fret 15 3 4 with fret Minimum Cavity Dimensions The diagram shows minimum dimensions required to install the RF24 Cavities having a combination of all the minimum dimensions shown possible may prove to be difficult installations IMPORTANT A free space of 3 4 inch 19 mm is required in front of the barrier screen ...

Page 17: ...cing flex pipes Four feet horizontal is permissible to allow for routing around masonry projections Do not bend flex pipe over a 45 degrees radius Flex liners may only be installed into solid fule burn ing fireplaces and chimney systems no combustible constructions The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Terminal Cap co axial Co axial a...

Page 18: ...uld not extend beyond vent if within 48 of termination cap Horizontal overhang Vertical wall Min 24 unvented soffit Min 36 vented soffit Termination cap Min 18 Storm collar Roof flashing H Roof Pitch Minimum H feet Flat to 7 12 1 over 7 12 to 8 12 1 5 over 8 12 to 9 12 2 over 9 12 to 10 12 2 5 over 10 12 to 11 12 3 25 over 11 12 to 12 12 4 over 12 12 to 14 12 5 Co Axial Co Linear Vent Terminal Loc...

Page 19: ...lace Ash Retaining Curbs Some fireplaces particularly factory built have a raised curb at the front edge to retain ashes Check the dimensions carefully to ensure the RF24 engine will fit behind any raised curb some curbs may be removed separately from the refractory base Gas Line Routing Plan the routing of the gas line before proceeding Utilize the existing hole for the gas line of the factory bu...

Page 20: ...e everything using the Pack Con tent sheet Also check that you have VENT PLATE Fuel bed packed separately Venting accessories Gas conversion kit if necessary Optional accessories if used Electrical accessories if used 4 Carefully read the Installer s Checklist included with the fireplace for the installation sequence Caution Only qualified licensed or trained personnel should install this applianc...

Page 21: ...r which in turn is hooked to the fireplace at hte top and attached with magnets at the bottom Grabbing both the screen and window cover pull the bottom to detach the magnets and unhook the top 2 Remove window Rotate the four fastening studs at the bottom corners and sides 90 degrees to release them Unhook window and keep in a safe place x 4 3 Remove items packed inside firebox 4 Strip firebox down...

Page 22: ... installing vent plate ensure rear edge of plate is hooked to cleat Cleat Vent plate Cleat Vent plate NOTE If the cavity where the appliance is to be installed is small you may want to secure the plate to the liners first then slide the plate with liners attached onto the appliance in the cavity see next pages for more information In all case ensure the plate is hooked to the cleat at the back of ...

Page 23: ...ack of the firebox 3 Fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure liners to collars with hose clamps included and 2 tapping screws per liner 4 Slide the firebox onto the vent slider in the cavity taking care not to damage the liners Make sure that the rear edge of the slider is hooked over the cleat on the firebox Secure the vent slid...

Page 24: ... sheet metal screws and gear clamps provided Ensure liners are well secured and will not fall down the chimney 4 Apply a bead of sealant to top of chimney and seat 590FVK2 s flash ing onto sealant 5 Release the two screws retaining the vent slider plate to the front of the firebox Remove the plate from the firebox by sliding it towards the back of the firebox 6 Fit the two liners Secure with hose ...

Page 25: ...t the level of the firebox in the hearth Reinstall Burner Module NOTE If the circulating fan is to be installed it should be done at this point before installing the burner module See instructions packaged with the fan for details of its installation Reinstall the burner module using the 10 screws removed previously NOTE The upper baffle may be removed to gain more room for the screwdriver to instal...

Page 26: ...he clips located underneath top of appliance RF24JD CL shown same for CA Install Convection Baffle Extension Install the convection baffle extension sliding it on top of the firebox into the guides on each side Slide the extension in or out to allow convection air to flow under the smoke curtain of the existing fireplace At the maximum the extension must cover the smaller convection baffle At the minimu...

Page 27: ...ual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5kPa Failure to either disconnect or isolate the appliance during pressure testing may result in regulator or valve damage Consult your dealer in this case The minimum supply pressure is given on page 6 of this manual All piping and connections must be tested for ...

Page 28: ...against the front edge of the sheet metal sup port Slide the log towards the left hand side until the notch in the log touches the right angled return edge of the pilot shield as indicated 2 Place the front left log on the burner Slide it to wards the left until its narrow end rests in the notch of the rear log as indicated Rear log pushed to the left abuts the pilot shield 3 Place the top left lo...

Page 29: ... log 5 Locate the top right log on the two pins on the right side of the rear log Ensure a tight fit against he flat area around the pins in the rear log Notch in rear log Pin in front right log 6 Place the lower end of the center right log onto the pin on the front right log Rest the narrow in the notch into the rear log ...

Page 30: ...ion of the logs is critical to ensure the good performance of the appliance Platform Insert the platform sideways into the firebox and place it on top of the burner Logs 1 Identify the base log and place it in the cavity of the ceramic platform The protruding parts of the log in front should rest against the lip of the sheet metal log support behind the burner 2 Identify the rear log and place it ...

Page 31: ...ont left of the platform and rests the top part of the log into the notch of the rear log as indicated 5 Place the front log inserting its two pins into the two holes at the front of the platform The ends of the log should be oriented towards the front as the log should not hang over the inside edge of the platform Pebbles Six pebbles are supplied as decorative elements If used they should be plac...

Page 32: ...overheating resulting in dangerous conditions Damages caused by incorrect window installation is not covered by the Valor warranty Installation Refit Check Window Refit and Check Window 1 Hook the glass window to the firebox then fastten the four bolts pushing and turning them 90 degrees Verify that each bolt is properly hooked by feeling with your fingers and ensuring the pin of the bolt is hooke...

Page 33: ... holder supplied with the appliance and one high quality alkaline 9 V battery in the remote handset 3 Connect the battery holder cable supplied with the appliance to the receiver as shown 4 Connect the other end of the cable to the battery holder 5 Place the receiver and battery holder as shown un der the firebox Placement may vary with installed options 6 Use a heat resistant tie to gather any ex...

Page 34: ...set button until you hear one short an done long beeps Release the button after the second beep 4 Within the next 20 seconds press the small flame button on the handset until you hear two short beeps confirming the pairing is set If you hear a long beep the pairing has not been done or the wires are not connected correctly This is a one time setting only and is not required when changing the batte...

Page 35: ...ions depending of the fuel bed used the altitude and other considerations the flame picture may be improved by adjusting the aeration The need for adjustment should be determined ony by operating the appliance with the fuel bed and window installed and evaluating the flame picture after a 15 minute warm up Increasing aeration open will cause the flames to appear more transparent and blue showing m...

Page 36: ...eld 1 2 RF24JD CA shown same for CL Top Vent Shield if necessary The top vent shield is designed to install on top of the firebox in front of the vent plate to hide the vent plate and vent liners when visible Cut the top of the vent shield to size if necessary and place it in front of the vent plate as indicated Appliance Identification Data Plate Pull out data plate from underneath appliance and ...

Page 37: ...t of the barrier screen is kept clear at all times Fret Installation Fret Brackets RF24FK Installation 1 Screw 2 thumbscrews into each retainer tab 2 Fit the retainer tabs to each leg 1 screw per side 3 Fit the slotted holes in the fret brackets over the thumbscrews push the fret brackets downwards and tighten the screws Cast Iron Fret Installation 1 Adjust the screw heads on the back of the fret ...

Page 38: ...at the base of a light switch plate IMPORTANT The location of the remote control handset is important to insure proper temperature regulation To obtain a constant temperature we recommend that the handset should be between 3 and 15 feet away from the appliance but not directly above it We also advise that the handset should be located away from any other heat source and not in direct sunlight as t...

Page 39: ...tery Holder RESET Button PANEL red yellow Receiver red Interruptor Block IGNITOR Connector Optional 1265WSK Wall Switch Kit Combination Control Valve Antenna Main Valve Knob MAN Knob PILOT Thermocouple 8 Wire Cable bundled ON OFF Switch OFF ON ...

Page 40: ... À DVKLQJ OXPLQXP OH LEOH LQHU RU GLDPHWHU 127 SO OLQHU DSSURYHG WR 1 8 6 VXLWDEOH IRU YHQWLQJ JDV DSSOLDQFHV V PDQXIDFWXUHG E OH OH PDVWHU DQG RWKHUV R LQHDU 6HULHV 70 70 7 R LDO 9 ODVKLQJV 5RRI ODVKLQJ 9 7 7 69 5RRI ODVKLQJ 9 7 7 69 ODW 5RRI ODVKLQJ 9 7 69 0DVRQU ODVKLQJ 7 0 6 1RWHV ROORZ LQVWUXFWLRQV VXSSOLHG ZLWK HDFK PDQXIDFWXUHU V FRPSRQHQWV 7HUPLQDWLRQ FDSV PDQXIDFWXUHG E 5 QGXVWULHV RU PHU...

Page 41: ...de directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon ...

Page 42: ...DU WKH ÁRRr If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 ÀJ RFDWH WKH SLORW ÀJ LQVLGH RI ÀUHER DW HIW DQG VLGH ON OFF switch 1 in ON position MAN knob 2 in ON position set Flame Adjustment knob 3 to lowest setting 3 On the remote control handset press and hold the off button and large flame simultaneously a...

Page 43: ... returns to set mode turns the burner and WKH SLORW R DUJH ȵDPH EXWWRQ ȵDPHV up sets hours temperature 6PDOO ȵDPH EXWWRQ ȵDPHV GRZQ DQG R VHWV PLQXWHV temperature Current temperature F or C Current time 12 or 24 hour clock Modes Manual Temperature Timer Handset sensor Battery status Current programmed period Timer Period start or end Temp Timer Turn Fireplace ON Press buttons until you hear a shor...

Page 44: ...t adjustment TEMP Daytime Temperature Mode When pilot is lit room temperature is measured and compared to set temperature Flame height automatically adjusts to reach Daytime Set Temperature TEMP Night time Setback Temperature Mode When pilot is lit room temperature is measured and compared to set temperature Flame height automatically adjusts to reach Night Time Setback Temperature TIMER Timer Mod...

Page 45: ... P2 must be set in the following order during a 24 hour cycle P1 P1 P2 and P2 Day Time temperature high program period Night Time temperature low program period Default Settings Program 1 P1 06 00 am P1 08 00 am Program 2 P2 11 50 pm P2 11 50 pm Press SET to scroll to TIMER Setting P1 time high temperature Hold SET button until P1 is displayed and time ȵashes To set time hour minutes Press or wait...

Page 46: ...automatically extinguishes the pilot This feature helps the consumer realize cost beneȴts by automatically eliminating energy consumption during non heating months and limited use The programmed length of inactivity to activate the system is speciȴed by the appliance manufacturer and cannot be altered in the ȴeld Low Battery Indication Handset The battery icon will show when the bat tery needs to ...

Page 47: ...K385 30 Electrode 4001856 31 Electrode Retaining Nut 4001855 32 Thermocouple 4000061 33 Pilot Shield 4000144 34 Pilot Gasket 4000139 35 Pilot Mount 4000138 36 Pilot Mount Gasket 4000140 Description Part No 37 Pipe Valve to Main Burner incl olive nuts 4000065 38 Valve Tray 4001627 39 Rear Gasket 4000642 40 RH Side Gasket 4000643 41 Front Gasket 4000641 42 LH Side Gasket 4000644 43 Break off Olive Nu...

Page 48: ...og 4005383 76 RH Cross Log 4005381 77 Front Log 4005382 78 LH Cross Log 4005380 79 Small Beige Beach Pebble 3 4003087 80 Small Grey Beach Pebble 4003086 81 Brown Beach Pebble 4003082 82 Grey Beach Pebble 4003083 83 Platform 4005385 67 68 69 70 71 72 66 MF28LSK 73 83 74 75 78 76 77 82 81 80 79 MF28DWK ...

Page 49: ...al gas Propane gas 16 17 22 19 18 24 23 33 25 27 32 28 29 30 31 34 35 36 38 37 39 40 41 42 43 44 47 48 49 45 50 56 55 54 53 57 65 58 26 20 21 1 2 3 7 4 6 5 8 9 10 11 12 13 14 15 46 61 63 59 62 64 60 RA24FK RA24CA RA24CL 51 52 51b 51a ...

Reviews: