![Valor RetroFire RF24JDN Installation Manual Download Page 16](http://html1.mh-extra.com/html/valor/retrofire-rf24jdn/retrofire-rf24jdn_installation-manual_851901016.webp)
16
Co-Axial with RA24CA
Dimensions
Gas Inlet
3/8” NPT
Female
Gas Inlet
3/8” NPT Female
Optional Fret:
Mounting
Brackets
Optional Fan
Speed Control
Location
(this side at front)
Control Valve
Optional
Cast Fret
Maintain
a 3/4” gap
in front of
barrier
screen
Barrier
Screen
Levelling
Feet
Top View
1-3/8”
1-3/4”
26”
Window Cover & Barrier Screen
18-3/4”
15-7/8”
21-1/4”
19-3/4”
14”
- to screen
14-5/8”
- to brackets
15-3/4”
- w/fret
14”
%DɞHH[WHQGVWRȋ
7-1/4”
6-1/4”
1-1/8”
Adjustable
Convection
%DɞH
17-3/4”
23”
14”
26-1/2”
Centerline
Control
Valve
Location
Front Face of
Barrier Screen
4-3/16”
4-1/2”
24-1/2”
8”
27”
10”
RA24TB Fret (Black)
1225VFB Ventana Fret (Black)
RA24CV Fret (Vintage Iron)
Optional Frets
24-3/8”
7-5/8”
18”
18”
20”
27”
Height to Smoke Curtain
Minimum Insert Cavity
14” without fret
15-3/4” with fret
Minimum Cavity Dimensions
The diagram shows minimum dimensions required to install the RF24.
Cavities having a combination of all the minimum dimensions shown
possible, may prove to be di
ffi
cult installations.
IMPORTANT!
A free space of 3/4 inch (19 mm) is required in front of the
barrier screen to allow the window to move and relieve during a hard
start. The use of the optional fret sets this space with the fret bracket
installed.
However, when the fret is not used and the bottom cover is used
instead, this space immediately in front of the barrier screen must be
added to the minimum depth as a safety precaution.
It is very
important to ensure that the area immediately in front of the barrier