23
Connect Venting Using RA24CL Co-Linear Vent Plate with 2 - 3” liners
IMPORTANT: This appliance’s venting system is room sealed and therefore,
does not require room air to be used in the combustion process.
1. Rough-in two 3” diameter vent liners into the existing chimney
system from the roof. Be careful not to tear or damage the liners in
the process. It may be easier to install both liners at the same time
rather than one at a time. Leave plenty of liner at the bottom to
facilitate the connection of the liners to the vent slider.
It is best to
leave the top termination until later.
Designate and mark the top and bottom of one liner as
“EXHAUST” to avoid confusion later.
2. Release the two screws retaining the vent slider to the
front of the
fi
rebox. Remove the slider from the
fi
rebox by sliding it
towards the back of the
fi
rebox.
3. Fit the two liners
ensuring that the
exhaust
liner is connected to
the identi
fi
ed “EXHAUST” vent collar
. Secure liners to collars with
hose clamps (included) and 2 tapping screws per liner.
4. Slide the
fi
rebox onto the vent slider in the cavity taking care not
to damage the liners.
Make sure that the rear edge of the slider is
hooked over the cleat on the
fi
rebox.
Secure the vent slider to the
front of the
fi
rebox with two screws removed earlier.
5. From the roof, pull the liners and
fi
t the
fl
ashing.
6. Fit the terminal cap
ensuring that the exhaust liner is connected to
the exhaust vent collar
. Secure with 8 screws provided.
7. Seal the terminal and
fl
ashing from water penetration as required.
Vent slider
cleat
1
3
2
4
5
6
7
Connect Venting Using RA24CL Co-Linear
WARNING
Failure to position the parts in
accordance with these diagrams or
failure to use only parts specifically
approved with this appliance
may result in property damage or
personal injury.
Installation
Connect Venting—Co-Linear