61
Approved Venting Components
Venting Parts
Description
Venting Parts Code / availability by Manufacturer
DURA-VENT
SELKIRK
ICC EXCEL
DIRECT
SECURE
VENT
RLH
INDUSTRIES
AMERIVENT
MILES
INDUSTRIES
BDM
Pipes 4” x 6 5/8” ( ID x OD )
6” long
Galvanized
46DVA-06
4DT-06
TC-4DL6
SV4L6
— —
—
94610606
Black
46DVA-06B
4DT-06(B)
TC-4DL6B
SV4LB6
90410606B
7” long
Galvanized
—
—
—
—
—
4D7
—
—
Black
4D7B
9” long
Galvanized
46DVA-09
4DT-09
TC-4DL9
— —
—
—
94610609
Black
46DVA-09B
4DT-09(B)
TC-4DL9B
94610609B
12” long
Galvanized
46DVA-12
4DT-12
TC-4DL1
SV4L12
—
4D12
—
94610612
Black
46DVA-12B
4DT-12(B)
TC-4DL1B
SV4LB12
4D12B
94610612B
18” long
Galvanized
46DVA-18
4DT-18
— — —
—
—
94610618
Black
46DVA-18B
4DT-18(B)
94610618B
24” long
Galvanized
46DVA-24
4DT-24
TC-4DL2
SV4L24
—
4D2
—
94610624
Black
46DVA-24B
4DT-24(B)
TC-4DL2B
SV4LB24
4D2B
94610624B
36” long
Galvanized
46DVA-36
4DT-36
TC-4DL3
SV4L36
—
4D3
—
94610636
Black
46DVA-36B
4DT-36(B)
TC-4DL3B
SV4LB36
4D3B
94610636B
48” long
Galvanized
46DVA-48
4DT-48
TC-4DL4
SV4L48
—
4D4
—
94610648
Black
46DVA-48B
4DT-48(B)
TC-4DL4B
SV4LB48
4D4B
94610648B
Flashings
Roof Flashing
0/12-6/12
46DVA-F6
4DT-AF6
TF-4FA
SV4FA
—
4DF
(0/12-5/12)
— 949606012
Roof Flashing
7/12-12/12
46DVA-F12
4DT-AF12
TF-4FB
SV4B
—
4DF12
(6/12-12/12)
— 949606712
Flat Roof Flashing
46DVA-FF
— TF-4F
SV4F
—
—
—
949606001
Masonry Flashing
— —
TF-4MF
— —
—
559FSK
—
New Siding Flashing
—
—
—
—
—
—
658NSFK
—
V
arious V
enting System Parts
Wall Thimble
46DVA-WT
4DT-WT
TM-4WT
SV4RSM
— 4DWT
—
949064U
Storm Collar
46DVA-SC
4DT-SC
TM-SC
SV4AC
— 4DSC
—
94960608
Decorative Plate
46DVA-DC
4DT-CS
TM-4TR
TM-4TP
SV4PF
— 4DFPB
—
94940612
Cathedral Ceiling
Support
46DVA-CS
4DT-CCS
TM-4SS
— — 4DRSB
—
949506KT
Ceiling Firestop /
Floor Support
46DVA-FS
4DT-FS
TM-4RDS
SV4BF
— 4DFSP
—
94980612
TM-CS
SV4SD
Attic Radiation Shield /
Firestop
— ADT-AIS
TM-4AS
—
—
4DAIS12 (12”)
— 94930620A
4DAIS36 (36”)
Wall Strap
46DVA-WS
4DTWS
TM-WS
— — 4DWS
—
949164
Vinyl Siding Stando
ႇ
46DVA-VSS
4DT-VS
TM-VSS
SV4VS
— 4DHVS
—
94800615S
Elbow Strap / O
ႇ set
Support
46DVA-ES
4DT-OS
TM-OS
— —
—
—
949264
Terminal Guard
46DVA-WG
—
TM-HTS
— —
—
845TG
940164SHRD
TM-RHTS
658TG
Notes:
1.
Follow instructions supplied with each manufacturer’s components.
2.
Unless otherwise speci
¿
ed, all the parts and assemblies from the above table are to be used with 4” x 6-5/8” pipes.
3. Do not mix components from di
ႇ erent vent manufacturers.
4.
Termination caps manufactured by RLH Industries or American Metal Products are from Homestyle Chimney Collection and can be ordered in
one of the following
¿
nishes: a) aluminium; b) black powder coated; c) solid copper.
5.
Miles Industries Valor Co-linear adapter 1156CLA cannot be used with models 1600. Use only with models 1100, 1150, 1400, 1500 and 1700.
6.
The DVA5BV DV to BV adapter can ONLY be installed on the listed models 1100/1150.