The burner settings are:
We recommend that the fire is set at position 4 for the first 10 minutes after lighting
to warm up the chimney and so obtain full efficiency quickly.
If operating the appliance for long periods it is beneficial occasionally to change the
settings. This will also help to remove any carbon deposits that may form during
operation.
Note: If the fire goes out while setting the control, repeat the full lighting procedure. If
the fire repeatedly goes out, have the fire serviced.
To turn the fire off.
Partially depress the control knob and turn clockwise to OFF. Release the knob.
Wait at least 3 minutes after turning the fire off before relighting.
Lighting with a taper.
In the unlikely event of failure of the ignition
spark, the pilot can be lit with a taper or long spill
after the window surround has been removed.
Removal of the surround is described in the
"Window Glass" chapter on the next page.
Light the pilot by inserting the taper or spill below
the centre of the window while the control is kept
depressed at the 1/IGN position (See figure 3).
When the pilot has lit follow the rest of the
instructions in the section headed "To light the
fire".
Page 33
©
Baxi Heating U.K. Limited 2008.
OWNER GUIDE
Control Knob
Position
Burner appearance
1 / IGN
Centre section on low. Outer sections off.
2
Centre section fully on. Outer sections off.
3
Centre section fully on. Outer sections on low.
4
All sections fully on.