![Vaisala WXT510 User Manual Download Page 66](http://html1.mh-extra.com/html/vaisala/wxt510/wxt510_user-manual_849366066.webp)
User's Guide _______________________________________________________________________
66 ___________________________________________________________________ M210470EN-B
0183 (automatic) is sent in XDR or MWV format.
<cr><lf>
= Response terminator
NOTE
When using MWV wind messages in NMEA 0183, one of the R field's bits
1-6 must be 1.
Changing the settings
You can change the following settings:
-
Parameters included in the wind data message
-
Update interval
-
Averaging time
-
Speed unit
-
Direction correction
-
NMEA wind formatter
Make the desired setting with the following command. Select the
correct value/letter for the setting fields, see page 65. See also the
examples !
Command format in ASCII and NMEA 0183:
aWU,R=x,I=x,A=x,U=x,D=x,N=x
<cr><lf>
Command format in SDI-12:
aXWU, R=x,I=x,A=x,U=x,D=x,N=x
!
where
R, I, A, U, D, N
= The wind sensor setting fields, see page 65.
x
=
value for the setting
<cr><lf>
=
Command terminator in ASCII and NMEA
0183
!
=
Command terminator in SDI-12
NOTE
If averaging time [A] is greater than update interval [I], it shall be a
whole multiple of the update interval and at maximum 12 times
greater.
Example:
If I = 5 s, Amax = 60 s.