![Vaisala WXT510 User Manual Download Page 38](http://html1.mh-extra.com/html/vaisala/wxt510/wxt510_user-manual_849366038.webp)
User's Guide _______________________________________________________________________
38 ___________________________________________________________________ M210470EN-B
where
a
=
Device address (default=0)
R2
=
Pressure, temperature and humidity message query
command
<cr><lf>
=
Command terminator
Example of the response
(the parameter set is configurable):
0R2,Ta=23.6C,Ua=14.2P,Pa=1026.6H<cr><lf>
where
a
=
Device address
R2
=
Pressure, temperature and humidity query command
Ta
=
Air temperature (C =
°
C)
Ua
=
Relative humidity (P = RH%)
Pa
=
Air pressure (H = hPa)
<cr><lf>
=
Response terminator
To change the parameters and units in the response message and to
make other sensor settings, see Chapter 8, section
Pressure, humidity
and temperature sensor
, page
69.
Precipitation data message (aR3)
With this command you can request the precipitation data message.
Command format:
aR3
<cr><lf>
where
a
=
Device address (default=0)
R3
=
Precipitation message query command
<cr><lf>
=
Command terminator
Example of the response
(the parameter set is configurable):
0R3,Rc=0.0M,Rd=0s,Ri=0.0M,Hc=0.0M,Hd=0s,Hi=0.0M<cr><lf>