13
Installation instructions VRC 430f 0020042470_01
Screen
Title
screen
adjustable
operating values
(only display = A)
Remarks
Unit
Min.
value
Max.
value
Increment
Default
value
C21
Total system
parameters
Mode Auto_OFF
Defines how the heat-
ing is controlled out-
side the programmed
time window
Frost protec-
tion, ECO, en-
ergy sav
ECO
Frost protection
delay time
Delay in start of frost
protection function or
ECO function.
Hr
0
12
1
4
Max. pump blocking
time
If the flow target tem-
perature is achieved
for a longer period of
time, the heating is
switched off for the
prescribed pump block-
ing time (depends on
the external tempera-
ture)
Min
Off, 5
60
1
15
C22
Total system
parameters
Max. advanced
heating time
Before the start of the
first time window
Min
0
300
10
0
Max. heating switch
off time
Before the end of a
time window
Min
0
120
10
0
AT through-heating
When the outside tem-
perature is reached,
continuous heating is
active
°C
OFF,
-25
+10
1
Off
C23
Floor drying
Floor drying - day
See Section 6.4 Func-
tion floor drying
Day
0
29
1
0
Floor drying /flow
target (A)
See Section 6.4 Func-
tion floor drying
°C
in accord-
ance with
temperature
profile
C24
Service
Telephone number
Enter the phone
number to be called in
the event of a service
requirement
Changing the code
number
0000
9999
each 1
1000
Maintenance date
Day/Month/Year ad-
justable
C25
Tools
Outside tempera-
ture adjustment
Adjustment of outdoor
sensor
R
-5
5
1,0
0
Room temperature
correction
Adjustment of room
temperature sensor
R
-3
3
0,5
0
Display contrast
0
15
1
6
C26
Software versions
Software version
per module (A)
Display of version
number
Table 6.2 Screens, Expert technician level (continued)