Installation instructions VRC 430f 0020042470_01
12
Screen
Title
screen
adjustable
operating values
(only display = A)
Remarks
Unit
Min.
value
Max.
value
Increment
Default
value
C1
HC1
Information
Target flow temper-
ature (A)
Flow temperature tar-
get value
°C
1
Pump status (A)
On, Off
Remote control
Remote control con-
nected?
Room actual display
°C
Yes, no and
0.5
C3
Hot water
information
Sensor VF1 (A)
Actual value at flow
sensor 1 or internal
sensor for the heating
appliance
°C
1
Boiler status (A)
Off, CH
mode, WW
operation
C4
Hot water
information
Hot water target
value (A)
Hot water target tem-
perature of cylinder
°C
1
Cylinder sensor 1 (A)
Hot water actual tem-
perature of cylinder
°C
1
Circulation pump
status (A)
On, Off
C8
HC1
parameters
Heating circuit type
(A)
Status display
Heating cir-
cuit, inactive
Switch-on room
temp.
selectable with wall-
mounted controller or
remote control
none, switch
on, thermo-
stat
none
Summer operation
mode Offset
If outdoor temperature
> room target tempera-
ture + summer offset,
the appliance switches
off
R
0
30
1
1
C9
HC1
parameters
set-back temp
A set-back temp can be
specified for the peri-
ods between the time
windows.
If your heating engi-
neer has set the frost
protection function the
set-back temperature
will automatically be
5 °C. This is not dis-
played as a set-back
temperature.
°C
5
30
1
15
Heating curve
In accordance with dia-
gram in Section 4.7.3
of operating instruc-
tions
0,2
4
0,05-0,1
1,2
Minimum tempera-
ture
Minimum flow temper-
ature
°C
15
90
1
15
C16
Hot water param-
eters
Anti-legionella day
Day or block of days;
The cylinder is heated
up to 70 °C for an hour
OFF, MO, TU,
WE, TH, FR,
SA, SU, MO-
SU
OFF
Start time of Le-
gionella protection
0:00 24:00
0:10
4:00
Table 6.2 Screen, Expert technician level