Appendix
34
Installation and maintenance instructions HOME 0020224355_00
Dia-
gnostics
code
Parameter
Values
Unit
Increment, select, explanation
Default set-
ting
User-spe-
cific setting
Min.
Max.
d.84
Maintenance in
0
3000
h
Number of hours = Display value
x 10
300
Not
adjustable
d.85
Increase in the min. out-
put (heating and hot wa-
ter handling mode)
–
–
kW
1
→
Section "Technical data"
–
Adjustable
d.88
Flow rate limit value
for ignition in hot water
handling mode
0
1
–
0 = 1.7 l/min (no delay)
1 = 3.7 l/min (2 s delay)
0
Adjustable
d.90
Status of the eBUS room
thermostat
Current value
–
off = Not connected
on = Connected
–
Not
adjustable
d.91
Status DCF77
Current value
–
–
–
Not
adjustable
d.93
Setting the product code
0
99
–
1
–
Adjustable
d.94
Delete fault list
0
1
–
off = No
on = Yes
–
Adjustable
d.95
Software versions
–
–
–
1 = Main PCB
2 = Interface PCB
–
Adjustable
d.96
Default setting (reset)
–
–
–
0 = No
1 = Yes
–
Adjustable
d.128
Heating minimum target
value
10
75
℃
1
10
Adjustable
d.129
Minimum hot water tar-
get value
35
(com-
bination
unit)
45
(pure
boiler)
60
℃
1
35
(combination
unit)
45 (pure
boiler)
Adjustable
C
Status codes
–
Overview
Note
Since the code table is used for various products, some codes may not be visible for the product in question.
Status code
Meaning
Displays in heating mode
S.0
Heating mode: No requirement
S.01
Heating mode: Advance fan operation
S.02
Heating mode: Pump pre-run
S.03
Heating mode: Burner ignition
S.04
Heating mode: Burner on
S.05
Heating mode: Pump/fan overrun
S.06
Heating mode: Fan overrun
S.07
Heating mode: Pump overrun
S.08
Heating mode: Temporary shutdown after heating procedure
Displays in hot water handling mode
S.10
Hot water handling mode: Requirement
S.11
Hot water handling mode: Advance fan operation
S.13
Hot water handling mode: Burner ignition
S.14
DHW mode: Burner on
S.15
DHW mode: Pump/fan overrun
S.16
DHW mode: Fan overrun