Appendix
32
Installation
and
maintenance
instructions
ecoTEC
pro
0020244995_02
Code Parameter
Values or explanations
Default
setting
Own setting
D.018 Pump operating mode
1 = Comfort (continuously operating pump)
Internal pump is switched on when the heating flow tem-
perature is not at
Heating off
and the heat requirement
is enabled via an external controller
3 = Eco (intermittently operating pump)
Internal pump is switched on every 25 minutes for 5
minutes once the overrun time has elapsed
3 = Eco
D.019 Pump operating mode: 2-stage
pump
Setting for two-stage pump operating mode
0: Burner mode stage 2, pump flow/overrun stage 1
1: Heating mode and pump flow/overrun stage 1, hot
water handling mode stage 2
2: Automatic heating mode, pump flow/overrun stage 1,
hot water handling mode stage 2
3: Always stage 2
4: Automatic heating mode, pump flow/overrun stage 1,
hot water handling mode stage 1
2
D.020 Max. DHW temperature target
value
Adjustment range: 50-70 °C (
actoSTOR
65 °C)
65 °C
D.022 DHW demand
On, Off
Not ad-
justable
D.023 Heating mode status
Heating on, heating off (summer mode)
Not ad-
justable
D.025 Ext. eBUS signal: Cylinder char-
ging
On, Off
Not ad-
justable
D.026 Auxiliary relay
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extractor hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not active)
9 = Legionella protection pump (not active)
10 = Solar valve (not active)
2 = External
pump
D.027 Accessory relay 1
Switching of relay 1 on the VR 40 "2 in 7" multi-func-
tional module
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extractor hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not active)
9 = Legionella protection pump (not active)
10 = Solar valve (not active)
2 = External
pump
D.028 Accessory relay 2
Switching of relay 2 on the VR 40 "2 in 7" multi-func-
tional module
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extractor hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not active)
9 = Legionella protection pump (not active)
10 = Solar valve (not active)
2 = External
pump
D.029 Water circulation vol. actual value
Actual value in m
³
/h
Not ad-
justable