Conditions
: Connecting a limit thermostat for underfloor heating
▶
Remove the bridge and connect the limit thermostat to
the
Burner off
connection.
5.
Close the electronics box.
6.
For multi-circuit controllers, change
D.018
from
Eco
(in-
termittently operating pump) to
Comfort
(continuously
operating pump). (
→
Page 23)
5.9.6
Connecting additional components via
VR 40 ("2 in 7" multi-functional module)
1.
Install the components in accordance with the respect-
ive instructions.
Conditions
: Components connected to relay 1
▶
Activate
D.027
. (
→
Page 23)
Conditions
: Components connected to relay 2
▶
Activate
D.028
. (
→
Page 23)
5.9.7
Actuating the circulation pump according
to requirements
1.
Carry out the wiring.
2.
Connect the supply line for the external button using
terminals 1
(0) and 6 (functional drawing) on the X41
edge connector, which is supplied with the controller.
3.
Plug the edge connector into the PCB slot X41.
6
Operation
6.1
Operating concept
The operating concept and the display and setting facilities
of the operator level are described in the operating instruc-
tions.
An overview of the display and setting options in the installer
level can be found in the section "Overview of the installer
level". (
→
Page 17)
6.2
Installer level overview
S.31
Code
D.---
PF
P.--
D F
--/--
DP
6.3
Calling up the installer level
1.
Only call up the installer level if you are a competent
person.
2.
Press
and
("i") at the same time.
◁
S.xx
appears in the display (current unit status).
3.
Press
to access the installer level.
◁
Code
and
--
appear in the display.
4.
Set the value
17
(code) and confirm by pressing
.
5.
Press
to access the check programmes
(P)
and the
fault codes
(F)
and to return to the diagnostics codes
(D)
.
6.
Use
or
to set the required value and confirm by
pressing
.
7.
Confirm by pressing ( ).
8.
Press
to cancel a setting or exit the installer level.
6.4
Live Monitor (status codes)
Menu
→
Live monitor
Status codes in the display provide information on the pro-
duct's current operating mode.
Status codes
–
Overview (
→
Page 35)