CONNECTIONS
40
Fig. 8-7 Sensor connection digital (X22)
TIPS AND RECOMMENDATIONS!
Information about the connection X22 and half cycle communication
The connection is especially designed of the operation at the EMD4P. (The DOUT 1 for
half cycle communication is permanently reserved for the EMD4P)
TIPS AND RECOMMENDATIONS!
Information about the connection X22 for rail bus communication/PCB
The digital output DOUT 1 can be freely actuated through the rail bus by the stationary
PLC.
Type
Description
Connection X22
M12, A coded, 8 pole, bushing
Plug cycles
> 100
Contact
AU (gold)
Pin
Function
Description
1
DIN 3
Digital input 3
2
DIN 4
Digital input 4
3
DIN 5
Digital input 5
4
DIN 6
Digital input 6
5
+U
b
Supply v24VDC
6
DIN 7
Digital input 7
7
GND
Supply ground
8
DOUT 1
Digital output 1