TECHNICAL DATA
20
5
TECHNICAL DATA
Information
Basis
Description
Conformity and approval
CE
2014/35/EU
Low voltage directive
2014/30/EU
EMC directive
Person and equipment protection
Protection class
EN60529
IP54
All plug connectors that are not in use must
be closed with protective caps or blind plugs.
The USB cover screw connection must be
available.
Earth leakage current
EN61800-5-1
< 3.5mA
Insulation (control circuits)
EN61800-5-1
Safe separation from the grid through dual
(reinforced) insulation.
Insulation strength
EN61800-5-1
< 2000m installation height: Overvoltage
category III
> 2000m installation height: Overvoltage
category II
Protective measures
Against motor overtemperature (input PTC
or thermal contact), overcurrent at the out
-
put
EMC
Interference emission
EN61800-3
Adherence to the limit values for the second
environment (industrial area): Category C3
Interference resistance
EN61800-3
Adherence to the limit values for the second
environment (industrial area): Category C3
Ambient conditions
Climatical
Storage
IEC/EN60721-3-1
1K3 (-25 ... +70°C) < 6 months
1K3 (-25 ... +40°C) > 6 months
> 2 years - forming intermediate circuit ca
-
pacitors
Transport
IEC/EN60721-3-2
2K3 (-25 ... + 70°C)
100% switch-on time
IEC/EN60721-3-3
3K3 (-10 ... +45°C)
0 ... +40°C
70% switch-on time
3K3 (0 ... +50°C)
+40 ... +50°C reduce the rated output cur
-
rent by 2.5%/°C.
Installation height
< 4000m NHN
> 1000m reduce the rated output current by
5%/1000m
Mechanical vibration resistance
Storage
Germanischer Lloyd
Vibration test 1
Transport
EN60721-3-2
2M2