66
• Vacon
arfiff05 Standard AFE-II
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
Off
value
On
value
Control
Off
value
Control
On
Value
Off
value
On
value
Negative
Positive
Figure 2.
2 = Scale ABS Inverted
Inverted absolute value is scaled linearly between On and Off values.
Off
value
On
value
Control
Off
value
Control
On
Value
Off
value
On
value
Negative
Positive
Figure 3.
3 = SR
Input value is used to make a step change in the output between On and Off values.
4 = Scale ABS
Input values is scaled linearly between On and Off values.
5 = Scale Inverted
Inverted value is scaled linearly between On and Off values
P2.9.1.8
Control Signal Filtering TC
ID1586
This parameter is used to filter the scaling function output. This can be used, for
example, when unfiltered torque is used to control a parameter that needs stabilisation.