Parameters
vacon • 95
Local contacts: https://www.danfoss.com/en/contact-us/contacts-list/
Table 63. I/f start parameters
7.1.2.6
Group 3.1.4.13: Stabilators
Code
Parameter
Min
Max
Unit
Default
ID
Description
P3.1.4.12.1
0
1
0
534
0 = Disabled
1 = Enabled
P3.1.4.12.2
0.0
%
15.0
535
Output frequency limit below
which the defined I/f start cur-
rent is fed to motor.
P3.1.4.12.3
0.0
100.0
%
80.0
536
The current fed to the motor
when the I/f start function is acti-
vated.
Code
Parameter
Min
Max
Unit
Default
ID
Description
P3.1.4.13.1
TorqStabGain
0.0
500.0
%
50.0
1412
Gain of the torque stabilator in
open loop motor control opera-
tion.
P3.1.4.13.2
TorqStabGainFWP
0.0
500.0
%
50.0
1414
Gain of the torque stabilator at
field weakening point in open
loop motor control operation.
P3.1.4.13.3
TorqStabDampTC
0.0005
1.0000
s
0.0050
1413
Damping time of torque stabi-
lizer
P3.1.4.13.4
TorqStabDampTC
PMM
0.0005
1.0000
s
0.0500
1735
Damping time constant of torque
stabilizer for PM-motor.