4.5 Partial pressure of oxygen (ppO
2
)
The tolerable partial pressure of oxygen can be set by means of a MemoMouse
and the DataTalk software to between 1.2 and 1.95 bar (see page 76). The set
value and the information about the actual ppO
2
are not displayed.
Messages:
Depending on the mixture used and the setting of the maximum
ppO
2
the limit for an attention message is reached at different
depths. When the set maximum partial pressure is reached
Aladin
®
Pro Ultra sends an acoustic attention message and the
current depth display starts flashing.
Response:
Go to a smaller depth in order to diminish the danger of oxygen
intoxication.
The allowed maximum depth should not be exceeded or only for a short
period. Disregarding the warning can lead to oxygen intoxication.
44