74
7 Leaving the Diveplan-Mode
VI Uwatec
®
Aladin
®
Pro Ultra
If the contacts B and E are touched for about 3 seconds, Aladin
®
Pro Ultra falls
back into ready- or surface-mode. This also occurs three minutes after the
activation of the diveplan-mode.
On a short touch of contacts B and E the Aladin
®
Pro Ultra swit-
ches back to the scrolling no-stop times.
In order to completely leave the diveplan-mode, B and E must be
continually bridged until two acoustic bleeps have occured.
If two or more divers using computers are planning a dive, planning for all
divers has to be based on the dive computer showing the shortest no-stop
times. Failure to do this may lead to serious injury or death from decompression
sickness.
ft
DIVEPLAN
depth
dive time
max. depth
deco info
DECOSTOP
depth
dive time
max. depth
deco info
O
2
% MIX
3 s
or after 3 minutes
WARNING