49
5 Functions at the Surface
III Uwatec
®
Aladin
®
Pro Ultra
American
• If desaturation time reaches zero, the “tissue“ models of the Aladin
®
Pro Ultra
are desaturated and it switches into the sleep-mode.
• Desaturation time is determined either by oxygen or nitrogen saturation,
depending on which gas requires the longer desaturation time.
• Oxygen saturation (<CNS O
2
LIMIT>) is displayed and adjusted until the value
becomes 0%.
For the calculations of the desaturation and No Fly Time it is assumed that the
diver inhales air.
5.3 No fly time
The waiting period until the next flight is indicated as follows:<DO NOT FLY>.
Beside this indicator is the time in hours that should pass before a flight.
In some cases the no fly time is considerably longer than with previous models
(because of recalibrated desaturation time).
• Flying while the Aladin
®
Pro Ultra displays
may lead to serious
injury or death from decompression sickness.
• For the calculations of the desaturation and No Fly Time it is assumed that the
diver inhales air.
DO NOT FLY
III
h
h
DO NOT FLY
DESATURATION
depth
dive time
max. depth
deco info
%
CNS O
2
LIMIT
O
2
2
% MIX
% MIX
WARNING
WARNING