NX-7002N Installation Manual
Page 36
05/06/13
To Do This
Send This
Explanation
Example
Arm your system
arm
[
partition list
]
Arms the system remotely.
Instead of the partition
numbers you can use a
keyword ALL for all
partitions.
arm 1
to arm partition 1
arm 1 3
to arm partitions 1 and 3
arm all
to arm all partitions
Disarm your system
disarm
[
partition list
]
Disarms the system
remotely.
disarm 1
to disarm partition 1
disarm 1 3
to disarm partitions 1 and
3
disarm all
to disarm all partitions
Partarm your system
partarm
[
partition list
]
Partarms the system
remotely.
partarm 1
to arm partition 1
partarm 1 3
to arm partitions 1 and 3
partarm all
to arm all partitions
Get the status of the specified
zones
zone status
[
partition list
]
Sends the status of the
zone (s) to your phone
(open and bypassed
zones). Sending a
command without a
partition list returns
information for all
partitions.
zone status 1
to receive the message
with zone status from zones assigned
to partition 1
zone status all
to receive the
message with zone status for all zones
Get a list of zones with
problems
zone faults
[
partition list
]
Sends a list of zones with
problems to your phone.
Sending a command
without a partition list
returns information for all
partitions.
zone faults 1
to receive fault
information from zones assigned to
partition 1
zone faults all
to receive the message
with zone faults for all zones
Bypass zones
bypass
[
zone list
]
Bypasses the specified
zones.
bypass 1 3
to bypass zones 1 and 3
Read events from the event
log
events
[
number
]
events
[
range
]
Sends the specified event
or events from the event
log to the phone.
events 1
to read the last (newest)
event from the panel log
events 1 3
to read the last 3 events
from the panel log
events
returns the 10 most recent
events
Set a connection to a home
automation device
output
[
output_number
X10_house_code X10_unit
]
Connects a specified
home automation device.
output 2 A 1
to set output two to
control X-10 device with house code A
and unit number 1
Switch on X-10 outputs
on
[
output list
]
Switches on an X-10
output.
on 1 4 7
to switch on X-10 outputs 1, 4
and 7
on all
to switch on all X-10 outputs
Switch off X-10 outputs
off
[
output list
]
Switches off an X-10
output.
off 1 4 7
to switch off X-10 outputs 1, 4
and 7
off all
to switch off all X-10 outputs
Activate an auxiliary function
switch aux
[
output list
]
Changes the auxiliary
function that occurs when
it is activated, for example
by a button on a keyfob.
switch aux 1
to activate aux output 1
on the panel
Change your user code
user code
[
new user code
]
Changes your user code.
user code 0101
to change your own
user code to 0101
Change another user code
user code
[
user number new
user code
]
Changes another persons’
user code.
user code 2 0101
to change the user
code to 0101 for the user 2
Delete a user code
delete user code
[
user
number
]
Deletes a user code.
delete user code 2
to delete the user
code for the user 2
Start reporting
start reporting
Sends reports from the
NX7002.
start reporting
Stop reporting until system re-
arm
stop reporting
Stops reports being sent
form the NX7002 until the
system is rearmed.
stop reporting
Stop reporting until you start it
again
stop reporting permanent
Stops reports being sent
from the NX7002 until the
start reporting command is
sent.
stop reporting permanent
Register your phone
register
[
phone number user
number
]
The phone is registered
with your alarm system.
register 32444123456 2
to register
the number 32444123456 to user 2
Register your phone with a
new password
register
[
phone number user
number Password
]
The phone is registered
with your alarm system
register 32444123456 1 444444
to
register the number 32444123456 to
Summary of Contents for Interlogic NetworX NX-7002N
Page 15: ...NX 7002N Installation Manual Page 15 05 06 13 ...