37
4. Gate 1 or Gate 2 (Gate 1
and Gate 2 if dual gate)
operating speed has
slowed down
When the gate is running slow, the reason is low power. The
Sentry charge controller does not output any voltage or current
when disconnected from the battery, you cannot check the
charge controller by disconnecting from battery and measuring
output voltage. To check charge controller output, disconnect
from battery, measure battery voltage and note. Reconnect
charger and monitor battery voltage it should rise above the
battery voltage noted above.
Two things need to be considered.
1. Battery condition (replace or charge)
2. the 1/4” ring terminals located on the Plug N Go harness
which are connected to the battery. The ring terminals can
become corroded and need replacing over time.
Remove battery and have it load tested at a battery shop.
Replace if bad.
5. Single or Dual gate
installation will not
automatically close
If control switch number 1 is turned “ON” then the gate will
only auto close from the fully open position.
1. Locate the “Open/Close Command “push button; press the
button to verify that the gate will close. If gate closes correctly
then proceed to the steps below. If gate will not close go to
step 5.
2. Verify that control switch number 1 is turned “ON”. Gate must
be cycled once switch is turned “ON” for control board to
recognize switch setting.
3. If your installation is a single gate verify which linear actuator
connector (Gate 1 or Gate 2) on control board you are using.
Then verify that the control switch for that Gate is turned
“ON” and the other is turned “OFF”.
4. If photo eye or other safety accessory is connected to J2
then we need to verify correct operation of the accessory. To
determine if this might be the problem disconnect the wire
that is connected to J2 pin 5 and cycle gate to see if problem
persists. If gate auto closes, accessory disconnected is
holding gate open verify wiring and operation of device.
5. The receiver P2 relay could be set for latch open mode. To
verify: press the transmitter button 2 one time, then press the
transmitter button 1 one time and see if gate closes. If gate
closes, then the hold open mode was enabled. For more
information see page 22.