18
DS1723-024
ENDING CONFIGURATION
In the ‘Con
fi
guration’ menu which can be opened using the
icon on the top right, select the ‘Installer’
menu, type in the password (‘1937’) and select ‘Thermostat Settings’.
When the thermostat is activated, two other lines appear which can be used to:
Set the unit of measurement (°C or °F).
De
fi
ne the output of the thermostat to the boiler.
The output of the thermostat to the boiler can be de
fi
ned as follows:
IF Contact 2 was assigned to the ‘Thermostat’ function, then ‘Contact 2’ will automatically appear on this line
and there will be nothing to do: the choice is already
fi
xed.
IF instead you want to control the boiler in wireless mode, the line will be initially empty. Tap on it to open the
following page:
Tap on the ON button referred to the pair of buttons already previously con
fi
gured to control the MTR2000ER
relay. For example, tap on button 7. The adjacent OFF button will be automatically selected:
Tap on OK to con
fi
rm.
—
—
—
—
Summary of Contents for Note 2 1723 Series
Page 47: ...47 DS1723 024...