3.4.5
ALARM
This section is dedicated to the configuration parameters used by the DVR for recording and notifying alarms.
3.4.5.1
Motion
Select Motion in the side menu to open a page where to define the methods and actions to be taken in case of motion
alarm detection.
•
Channel:
this is used to select the channel with which the motion detection function is associated.
•
Enable:
this is used to enable/exclude the motion detection function for the selected channel.
•
Buzzer:
you can set if the buzzer will sound and how long when motion is detected (Disable, 10sec, 20sec, 40sec,
60sec);
•
Sensitivity:
allow you to set sensitivity level of motion detection from higher to low with 8 being the most sensitive.
•
Area:
Click the [Setup] button to enter into area setup interface shown as follow.
•
Post Recording:
you can set how long alarm record will last when alarm ends (10sec, 30sec, 1min, 2min, 5min).
•
Show Message:
You can set show the icon on the screen when motion alarm is detected. About icons type please
refer to Section 4.
•
Send Email
: this is used to send the alarm images to the configured email addresses (for more information, see
paragraph 3.4.4.2 - “Email set”).
•
Full screen:
you can set if the video is displayed in full screen mode when Motion is detected
•
Record Channel:
this is used to select the channels to be recorded following the alarm detected by the DRV from the
list shown.
•
Copy:
allow you copy current channel parameters to any other channel or all channels.