urmet domus elekta Manual Download Page 5

sec.3g 

−−−−

 

5

2 VOICE - Technical Manual

ELEKTA AND ELEKTA STEEL CALL MODULE

PARAMETER CONFIGURATION

Program the calling module after having installed it by con

fi

 guring the 

following parameters.

PARAMETER TABLE

Parameter

Description

Possible values

Language

Language used on the display

Č

eština, 

Deutsch, 

English, English 

UK, Español, 

Français, 

Italiano, Magyar, 

,

Nederlands, 

Polski, 

Português,   

Slovenš

čina

Module type

Select primary or secondary 

module. 

All system users may be called from 

the primary module. A secondary 

module may only call the users of 

the riser to which it belongs. Users 

who receive the call can identify 

the source of the call by the tone. 

Two secondary calling stations may 

be present in a riser and must have 

a different address (secondary 0 or 

1).

PRIMARY 

SECONDARY 

Multirise 

This indicates whether the system 

consists of several risers or not.

The operation will only appear 

if “PRIMARY” module type was 

selected.

YES, NO

Module ID

Identi

fi

 cation code of the calling 

module = door station number.

No two primary stations can have 

the same ID. Two secondary 

stations with the same ID but with 

different number may coexist (set 

0 if there is only one secondary 

module on the riser, set 0 and 1 if 

there are two). 

The ID of the secondary door unit 

must coincide with the riser ID.

For primary 

module: 0 ÷ 3

For secondary 

module: 0 ÷ 31.

Code type

Setting up the type of user code.

Physical code: 5 digits, 

consisting of riser number (00 

÷ 31) + apartment number (000 

÷ 127).

Logical code: up to four digits 

long, permitted values: 1 ÷ 

9999

Physical, 

Logical

Busy time

Time after which the current call 

may be interrupted by other calls.

   The same busy time must 

be programmed for all 

calling modules in the 

system.

        

Stoppable

This setting determines whether 

auto-on without audio or an 

intercom call can be interrupted by 

a call from the door unit.

   The same “Stoppable” 

setting must be programmed 

for all calling modules in the 

system.

YES, NO

Door lock 

release type 

and time

The door unit lock release type and 

lock output activation time.

The type may be:

SECRET: pressing the door opener 

button on an apartment station 

will activate the door unit output 

only after having received a call or 

during a conversation or following 

auto-on if a video connection has 

been established.

FREE: pressing the door opening 

button on an apartment station will 

activate the door unit output only 

if the door unit is con

fi

 gured  as 

primary station or if the user and 

the secondary door unit belong to 

the same riser. 

Type: SECRET, 

FREE 

Time: 0 ÷ 90 s

Password

Four-digit password for accessing 

the calling module programming 

mode. 

1000 ÷ 9999

LCD 

backlight

This is used to adjust the 

brightness of the display to adapt it 

to environment conditions. 

1 ÷ 5

Button 

sound

This enables a tone when a button 

is pressed. 

YES, NO

Multitouch 

call 

The parameter de

fi

 nes where to 

route the call generated by pressing 

at least three buttons at the same 

time (Multitouch call) if the system 

is not provided with concierge 

switchboard or if this is present but 

con

fi

 gured in NIGHT mode.

   This must be a physical 

code if the parameter is 

programmed.

XYABC, with 

XY = 00 ÷ 31 

ABC = 

000 ÷ 127

Welcome 

message

Message which appears on the 

main page of the menu on the 

calling module.

32 characters 

on 2 lines 

Time zone

Setting up the time zone of the 

calling module.

YES, NO

Date and 

time

For setting date and time of the 

calling module. 

Day

For setting the day of the week.

Postman

This allows to open the pedestrian 

doors (during the programmed 

time) simply by pressing the T or 

P button on the short-cut menu of 

the calling module. 

YES, NO

Names

This setting is used to pair names 

to user codes (user repository).

Up to 4200 

names

Vocal 

synthesis 

If active, calls and door opening 

events are described by speci

fi

 c 

voice messages in the set 

language.

YES, NO

Switchboard

To be activated if the video door 

phone system is provided with 

concierge switchboard. 

YES, NO

2VOICE ELEKTA CALL MODULE Ref. 1083/15 (50Hz) – 1083/25 (60Hz)

2VOICE ELEKTA STEEL CALL MODULE Ref. 1083/16 (50Hz) – 1083/27 (60Hz)

PARAMETER CONFIGURATION

Summary of Contents for elekta

Page 1: ...ION OF TERMINALS 4 PROGRAMMING 4 Menu structure 4 Default configuration 4 Parameter configuration 5 Programming procedure 6 Bluetooth programming 13 SECTION FOR USERS HOW TO USE THE CALLING MODULE 14...

Page 2: ...door Unrestricted free or privacy electrical lock management Audio repeat device control for use with hearing aid optional Mail delivery function direct opening of pedestrian door by pressing the T or...

Page 3: ...ng module with the finishing frame which is fixed using two Torx screws INSTALLATION Ref 1083 16 1083 27 Arrange the duct so that it ends at the lower hole of the flush mounting box Remove the lower c...

Page 4: ...50Hz 1083 27 60Hz VOLUME ADJUSTMENT DESCRIPTION OF TERMINALS PROGRAMMING PROGRAMMING MENU STRUCTURE CODE TYPE AUTOMATIC FIT BUSY TIME STOPPABLE DOOR LOCK RELEASE TIME 1 OPEN DOOR 1 DOOR LOCK RELEASE T...

Page 5: ...NO Door lock release type and time The door unit lock release type and lock output activation time The type may be SECRET pressing the door opener button on an apartment station will activate the door...

Page 6: ...display Contact Urmet Customer Care and read the SERVICE CODE The Urmet operator will supply a temporary password PT IMPORTANT The PT you will be given can be used to access configuration until the ca...

Page 7: ...to confirm See the Parameter table for more information on PHYSYCAL and LOGICAL mode The AUTOMATIC FIT function automatically replaces physical codes with sequential logical codes from 1 to 127 accord...

Page 8: ...ling module must generate a feedback tone when a button is pressed using the buttons and press OK to confirm Enter the physical code of the extension where to route the call generated by pressing at l...

Page 9: ...d to the SE SE terminals and to the C NC NO relay contacts by pressing the T or P button in the short cut menu of the calling module The time slots during which the postman function is activated can b...

Page 10: ...New Enter the new NAME using the keypad special characters can be added like on a mobile phone by pressing buttons 1 and 0 and press OK to confirm the entered name The name may be up to 32 characters...

Page 11: ...required It is not necessary to pair each name to a door code but it is not possible to allocate the same code to different names Press C on the short cut menu to enter the digit to the left of the cu...

Page 12: ...esent is confirmed The page shown here by the side will appear and the keypad will be deactivated for approximately three seconds if the code length is incorrect The new code will be added to the data...

Page 13: ...press OK to confirm Press OK to confirm the reset operation or X to cancel and go back to the main menu BLUETOOTH PROGRAMMING The calling module can be programmed directly or alternatively using a per...

Page 14: ...ning an error message will appear for two seconds if an incorrect code is entered A confirmation message will appear on the display The warning message shown by the side will appear if the line is bus...

Page 15: ...meric string using the and buttons Press the X button to go back to the home page A page containing an error message will appear for two seconds if an incorrect code is entered If the code inserted is...

Page 16: ...tation to start an audio video conversation Press X to end the communication on the calling module and go back to the main page SPECIAL CODES To send a special code press and hold the 0 key for at lea...

Page 17: ...CKS menu described below The following screenshot shows an example of configuration for calling six blocks If the user wants to call a single block from the PRIMARY calling module the BLOCKS INTERVAL...

Page 18: ...proximately three seconds This page appears if an attempt to assign a name which was previously used for another block is made The system will automatically go back to the block modify page after appr...

Page 19: ...OK to confirm the selection Key in the number of the apartment to be called using the numeric keypad and press the or OK button to confirm Select the block to which the apartment to be called belongs...

Page 20: ...20 sec 3g 2 VOICE Technical Manual ELEKTA AND ELEKTA STEEL CALL MODULE...

Reviews: