![urmet domus elekta Manual Download Page 4](http://html1.mh-extra.com/html/urmet-domus/elekta/elekta_manual_1062332004.webp)
4
−−−−
sec.3g
2 VOICE - Technical Manual
ELEKTA AND ELEKTA STEEL CALL MODULE
VOLUME ADJUSTMENT
The microphone and speaker volumes are calibrated by default and
may be suitable for most installations. Use a screwdriver to adjust the
corresponding potentiometer to adjust one or both volumes.
DESCRIPTION OF TERMINALS
S+ S- LINE
SE2
C NC NO
ILA + - CT PA SP
SE+
Pedestrian electrical lock with capacitance discharge
actuation positive
SE-
Pedestrian electrical lock with capacitance discharge
actuation negative
LINE
Two-wire bus line in
LINE
SE2
Relay electrical lock (NO - normally open contacts) (vehicle
entrance)
SE2
C
Auxiliary relay output - common contact (for pedestrian
door)
NC
Auxiliary relay output - normally closed contact (for
pedestrian door)
NO
Auxiliary relay output - normally opened contact (for
pedestrian door)
ILA
Hearing aid device output
ILA
+
Not used
-
Not used
CT
Hall button and door sensor common contact
PA
Hall button
SP
Door detector
Default
2VOICE ELEKTA CALL MODULE Ref. 1083/15 (50Hz) – 1083/25 (60Hz)
2VOICE ELEKTA STEEL CALL MODULE Ref. 1083/16 (50Hz) – 1083/27 (60Hz)
VOLUME ADJUSTMENT - DESCRIPTION OF TERMINALS
PROGRAMMING
PROGRAMMING
MENU STRUCTURE
CODE TYPE
AUTOMATIC FIT (**)
BUSY TIME
STOPPABLE
DOOR LOCK RELEASE TIME 1
OPEN DOOR 1
DOOR LOCK RELEASE TIME 2
OPEN DOOR 2
PASSWORD
LCD BACKLIGHT
BUTTON SOUND
MULTITOUCH CALL
WELCOME MESSAGE
TIME ZONE
DATE AND TIME
POSTMAN
VOCAL SYNTHESIS
NEW
MODIFY
DELETE
DELETE ALL
LANGUAGE
CONFIGURATION
NAMES
DOOR OPENER
KEYS
RESET
NEW
MODIFY
DELETE
DELETE ALL
NEW
DELETE
DELETE ALL
ID SECONDARY MODULE
ID PRIMARY MODULE
RISE NUMBER
MODULE TYPE
GUI (*) SEMPLIFICATA
MULTIRISE
SECONDARY
PRIMARY
SWITCHBOARD (***)
—
(*) GUI = Graphic User Interface.
(**) Voice present only for some con
fi
gurations.
(***) Voice CAN BE CONFIGURED only if the calling module is
con
fi
gured as PRIMARY.
DEFAULT CONFIGURATION
Language: ITALIAN
Module type:
PRIMARY
Multirise: NO
Module ID:
0
Code type:
Physical
Busy time:
30 s
Stoppable: NO
Door lock release type and time: Type: SECRET;
Door Lock 1 release time: 1 s;
Door Lock 2 release time: 0 s
Password: 1000
LCD backlight:
3
Button sound:
Yes
Multitouch call:
Empty
Welcome message: URMET
Time zone:
NO
Date and time:
EMPTY
Day:
MONDAY
Postman: NO
Vocal synthesis:
NO
Switchboard: NO
To restore the default values, to power supply the device
by holding down the X, 8 and 6 keys.