urmet domus elekta Manual Download Page 2

−−−−

 

sec.3g

2 VOICE - Technical Manual

ELEKTA AND ELEKTA STEEL CALL MODULE

2VOICE ELEKTA CALL MODULE Ref. 1083/15 (50Hz) – 1083/25 (60Hz)

2VOICE ELEKTA STEEL CALL MODULE Ref. 1083/16 (50Hz) – 1083/27 (60Hz)

TECHNICAL SPECIFICATIONS - STRUCTURE

SECTION FOR INSTALLER

 

2VOICE ELEKTA CALL MODULE

Ref. 1083/15 (50Hz) – 1083/25 (60Hz)

2VOICE ELEKTA STEEL CALL MODULE 

Ref. 1083/16 (50Hz) – 1083/27 (60Hz)

1083/15 - 1083/25

1083/16 - 1083/27

The Elekta and Elekta Steel calling modules were created for 

fl

 ush-

mounting in outdoor environments.

The features of these call modules in the 2Voice two-wire system are 

the following:

Possibility of calling all potential system users (128 apartments 

on 32 risers, equal to 4096 apartments in total) by keying in a 

physical code or selecting the name directly (the name list can be 

scrolled or searched by initial). 

3.5” LCD graphic display with evolved GUI available in 12 

languages.

Alphanumeric keypad with optional button touch sound 

feedback.

Possibility of managing a repository containing up to 4200 names. 

A four-digit door opening code may be associated to each 

name.

Possibility of managing up to 100 door opening codes not 

associated to names for use by maintenance personal and 

cleaners.

Access control by means of transponder keys (up to 16384 keys, 

equal to four different keys per apartment; function available only 

for models 1083/15 and 1083/16).

CCD colour camera (#) with wide-angle lens and auxiliary LED 

lighting (#) at 50 Hz for Ref. 1083/15 and 1083/16; at 60 Hz for 

Ref. 1083/25 and 1083/27.

Infrared presence sensor for turning the display on automatically.

Pedestrian door electrical lock with capacitance discharge and 

hold current.

Auxiliary relay (NO) lock management for vehicle entrance electric 

lock.

Auxiliary relay lock management (C-NC-NO) activated jointly with 

capacitance distance lock (SE+, SE-) for the pedestrian door.

Unrestricted (free) or privacy electrical lock management.

Audio repeat device control for use with hearing aid (optional).

Mail delivery function: direct opening of pedestrian door by 

pressing the T or P button the short-cut menu on the programmed 

days and times.

Direct call to switchboard by pressing at least three buttons at the 

same time (emergency call).

Hall button management for pedestrian door.

Door detector management for pedestrian door.

Call and end of conversation con

fi

 rmation by means of messages 

on the display.

Call and door open con

fi

 rmation by means of speci

fi

 c  voice 

messages in the set languages (optional).

Speaker and microphone volume trimmer.

Bluetooth programmable using a personal computer (PC) or 

portable devices running the dedicated software.

TECHNICAL SPECIFICATIONS

Direct current power voltage (LINE) .................................

36 – 48 V 

Stand-by draw .................................................................

130 mA max

Max. draw (video conversation) ...............................................

200 mA

Lock output (SE+ SE-) 

Hold current: ......................

 270 mA max

  

Peak 

load: 

.......................................

15 VA

Relay contacts C, NC, NO

   

Max. switching voltage: .......  

30 Vdc/Vca

   

Max. switching current: .................. 

3.5 A

   

Max. switching load: ........  

40 VA – 25 W

Relay contact SE2 (driveway)

Max. switching voltage: ....................................................  

30 Vdc/Vca

Max. switching current: ........................................................... 

200 mA

ILA ........................Hearing aid compliant audio output, European law

 

SOCU0611477A

Max. distance between door opening button and call module         

 

25 m / 82 ft, wire cross section area 1.5 mm

2

 (AWG15)

Max. distance between door open detector and call module           

          

50 m / 164 ft, wire cross section area 1.5 mm

2

 (AWG15)

Operating temperature range ....................

-10 ÷ +50 °C / 14 ÷ 122 °F

Degree of protection  

codes. 1083/15 and 1083/25 ...........

IP44

           

codes. 1083/16 and 1083/27 ...........

IP43

LEGEND

Symbol

Explanation

 

DC supply voltage

 

STRUCTURE

5

4

3

2

1

6

7

8

9

10

5

4

3

2

1

6
7

8
9

10

1.

 

Transponder key reader (only for models 1083/15 and 1083/16)

2

. Keypad

3.

 Dynamically 

con

fi

 gured short-cut buttons.

 

The icon over the button indicates the available function

4.

 

Colour display, 320 x 240 pixel

5.

 

Camera with LED lighting

6.

 Speaker

7.

 

IR presenze detector

8.

 

Scroll buttons 1083/15 – 1083/25 

 

Scroll buttons 1083/16 – 1083/27 

9.

 Call 

button 

10.

 Microphone

Summary of Contents for elekta

Page 1: ...ION OF TERMINALS 4 PROGRAMMING 4 Menu structure 4 Default configuration 4 Parameter configuration 5 Programming procedure 6 Bluetooth programming 13 SECTION FOR USERS HOW TO USE THE CALLING MODULE 14...

Page 2: ...door Unrestricted free or privacy electrical lock management Audio repeat device control for use with hearing aid optional Mail delivery function direct opening of pedestrian door by pressing the T or...

Page 3: ...ng module with the finishing frame which is fixed using two Torx screws INSTALLATION Ref 1083 16 1083 27 Arrange the duct so that it ends at the lower hole of the flush mounting box Remove the lower c...

Page 4: ...50Hz 1083 27 60Hz VOLUME ADJUSTMENT DESCRIPTION OF TERMINALS PROGRAMMING PROGRAMMING MENU STRUCTURE CODE TYPE AUTOMATIC FIT BUSY TIME STOPPABLE DOOR LOCK RELEASE TIME 1 OPEN DOOR 1 DOOR LOCK RELEASE T...

Page 5: ...NO Door lock release type and time The door unit lock release type and lock output activation time The type may be SECRET pressing the door opener button on an apartment station will activate the door...

Page 6: ...display Contact Urmet Customer Care and read the SERVICE CODE The Urmet operator will supply a temporary password PT IMPORTANT The PT you will be given can be used to access configuration until the ca...

Page 7: ...to confirm See the Parameter table for more information on PHYSYCAL and LOGICAL mode The AUTOMATIC FIT function automatically replaces physical codes with sequential logical codes from 1 to 127 accord...

Page 8: ...ling module must generate a feedback tone when a button is pressed using the buttons and press OK to confirm Enter the physical code of the extension where to route the call generated by pressing at l...

Page 9: ...d to the SE SE terminals and to the C NC NO relay contacts by pressing the T or P button in the short cut menu of the calling module The time slots during which the postman function is activated can b...

Page 10: ...New Enter the new NAME using the keypad special characters can be added like on a mobile phone by pressing buttons 1 and 0 and press OK to confirm the entered name The name may be up to 32 characters...

Page 11: ...required It is not necessary to pair each name to a door code but it is not possible to allocate the same code to different names Press C on the short cut menu to enter the digit to the left of the cu...

Page 12: ...esent is confirmed The page shown here by the side will appear and the keypad will be deactivated for approximately three seconds if the code length is incorrect The new code will be added to the data...

Page 13: ...press OK to confirm Press OK to confirm the reset operation or X to cancel and go back to the main menu BLUETOOTH PROGRAMMING The calling module can be programmed directly or alternatively using a per...

Page 14: ...ning an error message will appear for two seconds if an incorrect code is entered A confirmation message will appear on the display The warning message shown by the side will appear if the line is bus...

Page 15: ...meric string using the and buttons Press the X button to go back to the home page A page containing an error message will appear for two seconds if an incorrect code is entered If the code inserted is...

Page 16: ...tation to start an audio video conversation Press X to end the communication on the calling module and go back to the main page SPECIAL CODES To send a special code press and hold the 0 key for at lea...

Page 17: ...CKS menu described below The following screenshot shows an example of configuration for calling six blocks If the user wants to call a single block from the PRIMARY calling module the BLOCKS INTERVAL...

Page 18: ...proximately three seconds This page appears if an attempt to assign a name which was previously used for another block is made The system will automatically go back to the block modify page after appr...

Page 19: ...OK to confirm the selection Key in the number of the apartment to be called using the numeric keypad and press the or OK button to confirm Select the block to which the apartment to be called belongs...

Page 20: ...20 sec 3g 2 VOICE Technical Manual ELEKTA AND ELEKTA STEEL CALL MODULE...

Reviews: