![urmet domus elekta Manual Download Page 3](http://html1.mh-extra.com/html/urmet-domus/elekta/elekta_manual_1062332003.webp)
sec.3g
−−−−
3
2 VOICE - Technical Manual
ELEKTA AND ELEKTA STEEL CALL MODULE
2VOICE ELEKTA CALL MODULE Ref. 1083/15 (50Hz) – 1083/25 (60Hz)
2VOICE ELEKTA STEEL CALL MODULE Ref. 1083/16 (50Hz) – 1083/27 (60Hz)
INSTALLATION Ref. 1083/15 - 108 3/25
INSTALLATION Ref. 1083/16 - 1083/27
INSTALLATION Ref. 1083/15 - 1083/25
Arrange the duct so that it ends at the lower holes of the
fl
ush-
mounting box.
Embed the
fl
ush-mounting body Ref. 1145/53 at the given
height.
1,55
÷
1,60 m / 5.08
÷
5.25 ft
294 mm / 11.57"
45 mm
1.77"
118 mm
4.65"
(1,40 m / 4.59 ft)
(*)
For disabled or special needs users of the D1 type (elderly) and D2
type (lower limb motor dif
fi
culties),
the centre of the device
must
be arranged at a height comprised between 75 cm and 140 cm with
respect to the
fl
oor. For more details, see technical standard CEI
64-21:2016-12 – Residential environments. Systems suited for use
by people with disabilities or special needs.
Establish the electric connections (see speci
fi
c paragraph).
Fix the calling module to the
fl
ush-mounting box with the screws
provided. Complete the calling module with the
fi
nishing frame,
which is
fi
xed using two Torx ® screws.
•
•
•
•
INSTALLATION Ref. 1083/16 - 1083/27
Arrange the duct so that it ends at the lower hole of the
fl
ush-
mounting box.
Remove the lower cap from the wire hole (1).
Apply adhesive labels on the holes for the screws of the frame
(2).
Install
fl
ush-mounting box Ref. 1158/43 at indicated height (3).
Fix the frame to the
fl
ush-mounting body (4).
Establish the electric connections.
Fix the calling module to the frame (4).
ALTO
TOP
HAUT
A
ALTO
TOP
HAUT
B
ALTO
TOP
HAUT
1,55
÷
1,60 m / 5.08
÷
5.25 ft
298 mm / 11.73"
45 mm
1.77"
118 mm / 4.65"
(1,40 m / 4.59 ft)
1
3
2
(*)
For disabled or special needs users of the D1 type (elderly) and D2
type (lower limb motor dif
fi
culties),
the centre of the device
must
be arranged at a height comprised between 75 cm and 140 cm with
respect to the
fl
oor. For more details, see technical standard CEI
64-21:2016-12 – Residential environments. Systems suited for use
by people with disabilities or special needs.
ELECTRIC CONNECTIONS
Refer to the information contained in the system manual for
more information on wiring, maximum distances and reference
wiring diagrams.
The call module is provided with an extractable terminal board to
facilitate connection operations.
•
•
•
•
•
•
•
§