urmet domus elekta Manual Download Page 19

sec.3g 

−−−−

 

19

2 VOICE - Technical Manual

ELEKTA AND ELEKTA STEEL CALL MODULE

2VOICE ELEKTA CALL MODULE Ref. 1083/15 (50Hz) – 1083/25 (60Hz)

2VOICE ELEKTA STEEL CALL MODULE Ref. 1083/16 (50Hz) – 1083/27 (60Hz)

ANNEX

CALL MODULE OPERATION IN SIMPLIFIED GUI 

MODE

In order to use SIMPLIFIED GUI a person 

wanting to call from the calling module 

must know the name of the block of the 

apartment and the number assigned to 

the apartment to be called. For example, 

apartment 

234

 in 

BLOCK A

.

When the SIMPLIFIED GUI mode is 

active, calls to apartments are made as 

follows:

Press the 

 buttons to access the 

list of blocks that the calling module 

is enabled to call. 

The blocks are 

sorted in alphanumeric order by 

name

Press the 

 buttons to highlight 

the name of the block to which the 

apartment to be called belongs.

Press 

OK

 to con

fi

 rm the selection.

Key in the number of the apartment to 

be called using the numeric keypad 

and press the 

 or 

OK

 button to 

con

fi

 rm.

Select the block to which the apartment 

to be called belongs using the 

 

buttons and press 

OK

 to con

fi

 rm.

Key in the number of the apartment to be 

called on the calling module panel. The 

number will appear on the screen.

Press the 

 or the 

OK

 button to send 

the call.

  If SIMPLIFIED GUI mode is 

chosen on a calling module 

con

fi

 

gured to call a single 

block, simply key in the number 

assigned to the apartment and 
press the 

OK

 or 

 button to 

call. 

       The list of blocks will not be 

shown if only one block is 

present because this is the only 

block that can be reached by 

the calling module.

The user can also use the following 

commands or actuations that are 

described in the following points:

Opening the door using a door code

Opening the door using a transponder 

key

Opening the door using the postman 

function

Calls to switchboard

Auto-on function

Special codes

Summary of Contents for elekta

Page 1: ...ION OF TERMINALS 4 PROGRAMMING 4 Menu structure 4 Default configuration 4 Parameter configuration 5 Programming procedure 6 Bluetooth programming 13 SECTION FOR USERS HOW TO USE THE CALLING MODULE 14...

Page 2: ...door Unrestricted free or privacy electrical lock management Audio repeat device control for use with hearing aid optional Mail delivery function direct opening of pedestrian door by pressing the T or...

Page 3: ...ng module with the finishing frame which is fixed using two Torx screws INSTALLATION Ref 1083 16 1083 27 Arrange the duct so that it ends at the lower hole of the flush mounting box Remove the lower c...

Page 4: ...50Hz 1083 27 60Hz VOLUME ADJUSTMENT DESCRIPTION OF TERMINALS PROGRAMMING PROGRAMMING MENU STRUCTURE CODE TYPE AUTOMATIC FIT BUSY TIME STOPPABLE DOOR LOCK RELEASE TIME 1 OPEN DOOR 1 DOOR LOCK RELEASE T...

Page 5: ...NO Door lock release type and time The door unit lock release type and lock output activation time The type may be SECRET pressing the door opener button on an apartment station will activate the door...

Page 6: ...display Contact Urmet Customer Care and read the SERVICE CODE The Urmet operator will supply a temporary password PT IMPORTANT The PT you will be given can be used to access configuration until the ca...

Page 7: ...to confirm See the Parameter table for more information on PHYSYCAL and LOGICAL mode The AUTOMATIC FIT function automatically replaces physical codes with sequential logical codes from 1 to 127 accord...

Page 8: ...ling module must generate a feedback tone when a button is pressed using the buttons and press OK to confirm Enter the physical code of the extension where to route the call generated by pressing at l...

Page 9: ...d to the SE SE terminals and to the C NC NO relay contacts by pressing the T or P button in the short cut menu of the calling module The time slots during which the postman function is activated can b...

Page 10: ...New Enter the new NAME using the keypad special characters can be added like on a mobile phone by pressing buttons 1 and 0 and press OK to confirm the entered name The name may be up to 32 characters...

Page 11: ...required It is not necessary to pair each name to a door code but it is not possible to allocate the same code to different names Press C on the short cut menu to enter the digit to the left of the cu...

Page 12: ...esent is confirmed The page shown here by the side will appear and the keypad will be deactivated for approximately three seconds if the code length is incorrect The new code will be added to the data...

Page 13: ...press OK to confirm Press OK to confirm the reset operation or X to cancel and go back to the main menu BLUETOOTH PROGRAMMING The calling module can be programmed directly or alternatively using a per...

Page 14: ...ning an error message will appear for two seconds if an incorrect code is entered A confirmation message will appear on the display The warning message shown by the side will appear if the line is bus...

Page 15: ...meric string using the and buttons Press the X button to go back to the home page A page containing an error message will appear for two seconds if an incorrect code is entered If the code inserted is...

Page 16: ...tation to start an audio video conversation Press X to end the communication on the calling module and go back to the main page SPECIAL CODES To send a special code press and hold the 0 key for at lea...

Page 17: ...CKS menu described below The following screenshot shows an example of configuration for calling six blocks If the user wants to call a single block from the PRIMARY calling module the BLOCKS INTERVAL...

Page 18: ...proximately three seconds This page appears if an attempt to assign a name which was previously used for another block is made The system will automatically go back to the block modify page after appr...

Page 19: ...OK to confirm the selection Key in the number of the apartment to be called using the numeric keypad and press the or OK button to confirm Select the block to which the apartment to be called belongs...

Page 20: ...20 sec 3g 2 VOICE Technical Manual ELEKTA AND ELEKTA STEEL CALL MODULE...

Reviews: