30 |
Minimum
4"
102mm
1"
25mm
Maximum
Minimum
6"
152mm
6"
152mm
Minimum
2"
52mm
6"
152mm
Minimum
Wall Mounted Object
5 1/2"
[140mm]
5 1/2"
140mm
23"
584mm
2 1/2"
64mm
2 1/2"
[64mm]
20 3/4"
527mm
10"
256
Keep Hatched
Areas Open
Fireplace Footprint
Framing Valance
An optional valance can be added to any installation to help conceal
the heat release gap. Minimum opening and valance dimensions must
be followed to ensure safe heat dissipation. Combustible materiel
is acceptable when constructing the valance. Follow the minimum
dimensions below
Framing Pedestal
An optional pedestal can be added to any installation to
raise the unit further off the floor. Minimum opening and
pedestal dimensions must be followed to ensure safe
heat dissipation. Combustible materiel is acceptable when
constructing the pedestal.
The hatched area must be left unobstructed
in order for proper unit cooling. Do not
cover these areas for any reason. Unit must
sit on center blocks to hold the weight. The
center portion can be a solid block, the space
within the fireplace footprint can be used for
support.
Framing shown is an example and can be
constructed differently.
Framing and Installation
Framing and Installation