10 |
Unpacking and Initial Setup
Leg Height Adjustment
(Optional) Urbana units have adjustable legs and can raise
the height an additional 3" (76mm). This may be desired
depending on the install configuration. Adjust as follows:
1.
With help, gently lay the unit on its
back to access the adjustable legs.
A
A
A
A
B
B
B
B
Heat Shield Installation
The fireplace comes with two heat shields. The heat
shields are necessary for the safe fireplace operation. The
cabinet heat shield is mandatory for all installations, install
it as follows:
1.
The fasteners come pre-installed in the
shield; use a 1/4” socket to remove.
2.
Place heat shield underneath the cabinet
lip; resecure fasteners to install.
3.
(Situational) For later use, install the vent heat
shield above first wall pass-through. This only
applies to "up and out" venting configurations.
2.
Use a 3/8 socket with 6” extension (minimum) to
access fasteners. Remove side fasteners
(Labelled A).
3.
Remove end fasteners
(Labelled B)
4.
Adjust legs to desired height ensuring all 4 legs
are equal. *Legs can be adjusted in 1/2" increments.
5.