Unpacking and Initial Setup
Electrical Connection
WARNING: This fireplace must be electrically
connected and grounded in accordance with local
codes or, in the absence of local codes, with the
current CSA C22.1 Canadian Electrical Code Part 1,
Safety Standards For Electrical Installations, or The
National Electrical Code ANSI / NFPA 70 in the US.
Electrical Requirements:
120VAC 15A (dedicated circuit recommended). Appliance
receptacle must be hardwired with coated 14/2 AWG
(minimum) copper electrical wire such as Lumex or
Romex. Consult your electrical code for further details.
Wire your unit as follows:
1.
Run wire to rear of unit; be sure wire is NOT live.
2.
Use a 1/4 socket to remove outer electrical cover.
Fireplace Levelling
NOTES:
1: It is essential to level the unit from proper operation.
2: This step is not necessary when wall mounting unit.
All Urbana units come with levelling feet to accomodate
unever surfaces. Ensure the fireplace is in its final position
before proceeding.
Levelling feet come fully inserted; you will need to
unscrew the feet to see any adjustment (no lock nut used).
Adjust as follows:
1.
Use a level on the top of the unit to
determine which feet need adjustment.
2.
Use a 9/16 wrench to unscrew the feet
to make the necessary adjustments.
3.
Verify fireplace is level in all 3 planes.
3.
Remove inner electrical cover. Inside you will
find a plug and receptacle; unplug and remove.
4.
Run power wire through outer cover and into
receptacle box through the corresponding strain relief.
120V
5.
Wire receptacle
including ground wire.
6.
Reassemble
components and covers.
7.
Apply power and
ensure connection was
made successfully.