6. e
naBle
z
one
2
6.1 Select
Yes
to enable zone 2 in the controller.
Enable Zone 2
No
Yes
6.2 Select the setup of the zone.
Stand Alone Control
only uses the sensors and components connected to
the controller.
Smatrix Base PRO
uses a connected
Uponor Smatrix Base PRO system.
Domestic Hot
Water
(DHW) regulates the supply temperature for
DHW in the zone.
Zone Setup
Stand Alone Control
Smatrix Base PRO
Domestic Hot Water
6.3 Select heating mode.
Outdoor
only uses an
outdoor sensor, and
O Indoor comp.
also uses an room sensor to calculate the supply
temperature. The sensor/sensors are connected
to either the Move PRO controller (
Stand Alone
Control
) or to a connected Base PRO controller
(
Smatrix Base PRO
).
See section 5.7 Connect sensors to controller >
Outdoor sensor for more information
This setting is not shown if Domestic Hot Water is
selected in the Zone Setup menu.
Heating Mode
Outdoor
O Indoor comp.
6.4 Select which indoor temperature data in the Smatrix
Base PRO system to use when calculating the
supply temperature.
•
Worst Case
uses the room temperature from
the room (only rooms with a heating demand)
with the highest setpoint value in the zone.
•
Average
calculates the average from all
connected room thermostats in the zone
(selected in the Smatrix Base PRO interface
I-147).
This setting is only shown if Smatrix Base PRO is
selected in the Zone Setup menu, and if O
Indoor comp. is selected in Heating Mode.
Smatrix Indoor Temperature
Worst Case
Average
6.5 Set a minimum allowed supply temperature.
This setting is not shown if Domestic Hot Water is
selected in the Zone Setup menu.
Min. Supply Temp.
min: 5 max: 70
15˚C
6.6 Set a maximum allowed supply temperature.
This setting is not shown if Domestic Hot Water is
selected in the Zone Setup menu.
Max. Supply Temp.
min: 15 max: 90
70˚C
EN
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SK
3 1