Unisight Digital Technologies
Unisight DVR Server/Web Server to be accessible from remote locations you must forward
ports through the router to the DVR machine. To configure which port is used select the
Network Ports
button. The Network Ports Setting dialog box will appear. (Fig. 2-23) Input
the desired port number for the HTTP Port, which is used for the Web Client, and the Server
Message, which is used for the Client Application.
(Fig. 2-23)
To synchronize the system clock to the local time select the
Adjust Clock
button. (Fig.
2-24) The System Clock dialog box will appear and allow you to change the system time and
date.
(Fig. 2-24)
The Auto Reindex Recording Files check box will automatically start the reindexing
process after the Unisight DVR Server application finishes loading. Due to imperfections in
hard disk drive technology data corruption may occur. In this case you will need to reindex
the recording files. The reindexing process scans each recorded video file and recreates the
index file. Depending on how many recorded video files there are on the storage partitions
this process may take up to two hours. If recorded video does not appear in the Playback
mode or if the Playback mode takes more than five minutes to load it may indicate that there
are missing or corrupt index files, you will need to reindex. During Daylight Savings when the
time is set back one hour the Unisight DVR Server will have two recordings for that same
hour. To correct this situation you must reindex.
27