SECTION D, PAGE
7
SOLUTION
IN PRODUCTION
Number of times the
WELD TIME
will
repeat with
PULSATION COOL
cycles
between the
WELD
pulses. The example
in section D2.4
3 PULSES
of
2 WELD
CYCLES
each.
Increasing heat starting at the
Start
UPSLOPE%
and finishing at the
WELD
HEAT%
over the
UPSLOPE TIME.
Decrease heat starting at the
WELD
HEAT%
and finishing at the
DOWNSLOPE at END%
over the
DOWNSLOPE TIME.
Fixed heat of
POSTHEAT%
over
POSTHEAT TIME.
QUENCH =
non-heat time before
TEMPER
sequence.
Fixed heat of
TEMPER HEAT%
over
TEMPER TIME.
NUMBER OF PULSES 00
←
PULSATION COOL 00CY
UPSLOPE TIME 00CY
←
Start USLOPE at 00%
PULSATION
is handy to use when welding thick metal (.120” or thicker).
Divide the number of weld cycles found on a welding chart for this
thickness by 5 and Set
PULSATION COOL = 3
.
PULSATION
can also be useful for welding very near the edge of a
sheet. If set properly it will minimize metal expulsion from the edge.
or when welding near the edge of a sheet.
DOWNSLOPE TIME 00CY
←
DOWNSLOPE at END00%
POSTHEAT TIME 00CY
←
POSTHEAT 00%
TEMPER TIME 00 CY
←
TEMPER HEAT 00%
QUENCH TIME 00CY
QUENCH & TEMPER
sequence is useful for welding spring steel or
other higher-carbon metals. The
QUENCH TIME
lets the nugget
area cool down, and the
TEMPER TIME
reheats the nugget to a
lower temperature to increase ductility of the weld nugget and area
around the weld nugget.
Summary of Contents for SOLUTIONi
Page 1: ...DIRECTION BOOK POWERFULLY INTUITIVE...
Page 4: ...SOLUTION INSTALLATION SECTION A...
Page 13: ...HOOK UP DRAWINGS SECTION A PAGE 8 FOR CONTROLS WITH REMOTE CONSOLES PAGE 1 OF 2...
Page 14: ...HOOK UP DRAWINGS SECTION A PAGE 9 FOR CONTROLS WITH REMOTE CONSOLES PAGE 2 OF 2...
Page 15: ...HOOK UP DRAWINGS SECTION A PAGE 10 FOR CONTROLS WITH ALL COMPONENTS IN ONE CABINET PAGE 1 OF 3...
Page 16: ...HOOK UP DRAWINGS SECTION A PAGE 11 FOR CONTROLS WITH ALL COMPONENTS IN ONE CABINET PAGE 2 OF 3...
Page 17: ...HOOK UP DRAWINGS SECTION A PAGE 12 FOR CONTROLS WITH ALL COMPONENTS IN ONE CABINET PAGE 3 OF 3...
Page 21: ...SOLUTIONi FIRST TIME CONTROL SETUP SECTION B...
Page 48: ...SOLUTION PERSONALIZATION SECTION C...