FIRST TIME CONTROL SETUP
SECTION B, PAGE 9
B6. ENTERING THE CYLINDER AREA:
After entering the air cylinder area into the display:
Push The display will now show:
B7. FORGE DELAY:
This is a fairly
uncommon
function on welders. But if
your welder has an
extra solenoid valve
and
pressure regulator
for
BACKUP
(sometimes called
BUCKING) PRESSURE
, enter the air pressure that you will set
on that pressure regulator. A typical value is 20psi.
If you
do not
have this FORGE DELAY system installed on your welder, leave the
value at 00.
Press and the display will show:
If you disconnect the air coming into the welder and
the electrodes do not close by gravity, press:
and skip to B8.
YES
YES
But be sure that whatever you enter into this display for
BACK-UP
PRES.
will match what you
set
on the BACK-UP pressure regulator on
the welder. Otherwise all of the TIP FORCE calculations will be
incorrect.
SKIP
NO
Area of CYLINDER is
00.0 SQUARE INCHES
After entering data
Press YES
For FORGE DELAY:
BACKUP PRES.= 00 PSI
After entering data
Press YES
HEAD WEIGHT = 000LB
Want to change? PUSH
The YES or NO button
Summary of Contents for SOLUTIONi
Page 1: ...DIRECTION BOOK POWERFULLY INTUITIVE...
Page 4: ...SOLUTION INSTALLATION SECTION A...
Page 13: ...HOOK UP DRAWINGS SECTION A PAGE 8 FOR CONTROLS WITH REMOTE CONSOLES PAGE 1 OF 2...
Page 14: ...HOOK UP DRAWINGS SECTION A PAGE 9 FOR CONTROLS WITH REMOTE CONSOLES PAGE 2 OF 2...
Page 15: ...HOOK UP DRAWINGS SECTION A PAGE 10 FOR CONTROLS WITH ALL COMPONENTS IN ONE CABINET PAGE 1 OF 3...
Page 16: ...HOOK UP DRAWINGS SECTION A PAGE 11 FOR CONTROLS WITH ALL COMPONENTS IN ONE CABINET PAGE 2 OF 3...
Page 17: ...HOOK UP DRAWINGS SECTION A PAGE 12 FOR CONTROLS WITH ALL COMPONENTS IN ONE CABINET PAGE 3 OF 3...
Page 21: ...SOLUTIONi FIRST TIME CONTROL SETUP SECTION B...
Page 48: ...SOLUTION PERSONALIZATION SECTION C...