SECTION C, PAGE 15
SOLUTION
PERSONALIZATION
If you are in this mode, a new line will appear in all welding programs:
In this mode, the solenoid valve connected to
SV1
turns on first to bring the
electrodes closed under low advance fluid force. After the
INTENSIF. DELAY
time, the solenoid valve connected to
SV0
turns on to put full welding force on the
electrodes.
Push and the display will show the rest of the choices:
C10.3 CLAMP DELAY:
Press 4 and the display will show:
Push to use this mode. This is useful for operations that need to clamp a
part first before bringing the welding electrode down.
Push and the display will show:
INTENSIF. DELAY 00
←
00CY
←
BLOCK
SVO FUNCTION IS:
CLAMP DELAY =4
TURN ON W/LEVEL 2=5
“SOFT TOUCH” =6
NO
YES
CLAMP(SV1) delay OFF
after SV0 turns OFF.
CLAMP (SV1) ON. Then
SV0 ON after DELAY.
Want to change? Push
the YES or NO button
Summary of Contents for SOLUTIONi
Page 1: ...DIRECTION BOOK POWERFULLY INTUITIVE...
Page 4: ...SOLUTION INSTALLATION SECTION A...
Page 13: ...HOOK UP DRAWINGS SECTION A PAGE 8 FOR CONTROLS WITH REMOTE CONSOLES PAGE 1 OF 2...
Page 14: ...HOOK UP DRAWINGS SECTION A PAGE 9 FOR CONTROLS WITH REMOTE CONSOLES PAGE 2 OF 2...
Page 15: ...HOOK UP DRAWINGS SECTION A PAGE 10 FOR CONTROLS WITH ALL COMPONENTS IN ONE CABINET PAGE 1 OF 3...
Page 16: ...HOOK UP DRAWINGS SECTION A PAGE 11 FOR CONTROLS WITH ALL COMPONENTS IN ONE CABINET PAGE 2 OF 3...
Page 17: ...HOOK UP DRAWINGS SECTION A PAGE 12 FOR CONTROLS WITH ALL COMPONENTS IN ONE CABINET PAGE 3 OF 3...
Page 21: ...SOLUTIONi FIRST TIME CONTROL SETUP SECTION B...
Page 48: ...SOLUTION PERSONALIZATION SECTION C...