10
© 2023 United States Stove Company
US Stove highly recommends your stove be installed by a
qualified NFI (US) or WETT (Canada) technician. To find
the nearest qualified installer, go to:
https://nficertified.org
,
https://www.wettinc.ca/
FLOOR PROTECTOR
The furnace must be placed on solid concrete, solid
masonry, or when installed on a combustible floor, on a
floor protector. The floor protector is required to provide
heat, live ember, and ash protection and must be of a non-
combustible, continuous solid surface to protect against
infiltration of live embers and ash. Floor protection must
have and R-Value of at least 1.4. Refer to floor protector
manufacturer’s instructions for installation directions.
The floor protector or non combustible floor must extend
under the furnace and beyond each side as shown below.
Dimension
Inch
mm
A Front
24
609.6
B Flue Rear
2
50.8
C Side
8
203.2
A
C
C
B
FLUE
CLEARANCES TO COMBUSTIBLES
The installation of this furnace includes supplying
electrical power, return air ductwork, and supply air
ductwork. This furnace may be installed as a stand alone
wood furnace only. See installation section in this manual
to ensure proper assembly, installation and operation
of your new furnace. If installing in an area with a fan it
should not be allowed to create negative pressure in the
room where the furnace is installed. When locating your
furnace ensure the required maintenance clearances are
maintained. Your furnace must be installed as shown in
this manual and in compliance with all local and national
codes. It is of the utmost importance that the clearances
to combustible materials be strictly adhered to during
installation of the furnace. Refer to the table and diagrams
below for minimum required clearances.
Dimension
Inch
mm
D Backwall To Furnace
26
661
E
Sidewall To Furnace
16
407
F
Sidewall To Flue
25
635
G Backwall To Flue
18
458
H Supply Duct (first 6 feet)
6
153
J
Supply Duct (after first 6 feet)
2
51
K Minimum Duct Height
8
204
L
Top Of Door To Ceiling
48
1220
M Minimum Ceiling Height
75
1905
Back wall
Side w
all
Side w
all
F
E
D
Ceiling
Floor Protector
H (First 6ft)
J
K
L
M
G
INSTALLATION
FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050
FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050