24
5. Replace the cap back on the regulator
6. Remove the grates, burners and burner caps from the range to
access the orifices.
7. Use a 7mm wrench to remove the orifices. Each orifice can be
accessed easily - the larger burner orifice is located on the burner wall.
Burner Orifice
8. Remove all NG orifices, place in the bag and store in a safe place.
9. Take the LPG orifices provided and install them as shown below.
See below for rating of orifice for each model
Smallest
Medium x 2
Largest
Oven
Broil
LPG
0.53 mm
0.68/0.9 mm
1.00 mm
0.82 mm
0.8 mm
10. Once all the orifices are installed, replace all burners and burner caps, then fire
up the burners to check the minimum flame height.
GAS RANGE CONVERSION
LPG
NG