10.Multi-Hold Mode
60
10-3-9-3. Inflection Point Hold C
tt1: Delay time between the instant when the indicated value exceeds the hold start level
and the instant when the hold is detected.
Ts msec (max.)
t2: Delay time between the instant when the H/M signal is input and the instant when it is
detected that the indicated value exceeds the hold start level.
Ts+0.8msec (max.)
t3: Delay time between the instant when the H/M signal is cancelled and the instant when
the hold is determined.
Ts+0.8msec (max.)
t4: Delay time between the instant when the T/H signal is input and the instant when the
indicated value returns to tracking.
Ts+0.8msec (max.)
t4
t
+
H/M
t2
t1
OFF
ON
OFF
ON
OFF
ON
COMPLETE
t3
ON
OFF
T/H
Hold Start
Level
Sensor input value
Indicated value
Detection/hold period
Hold period
Indeterminate
period (Note
Determination
Note: During the indeterminate period, the Judgment output varies with
variations in the input waveform. However, the COMPLETE output is
kept on during the indeterminate period. Read the result of judgment
after determination of the judgment by turning off the H/M signal.
High/Low
Limit
Output
Judgment